ÎªÔ°ÇøÍøÂç½ÓÈëÉ豸ÌṩǧÕ×µ½×ÀÃæµÄÓ¦Óã¬Í¬Ê±Âú×ã°²·À¼à¿Ø¡¢µç»°»áÒéϵͳ¡¢ÎÞÏ߸²¸ÇµÈ³£¼ûPoE¹©µçµÄÐèÇó¡£
ÀàÐÍ£º
²úÆ·ÌØÐÔ£º





| ³ß´çÓëÖØÁ¿ | RG-S2910-24GT4SFP-L | RG-S2910-48GT4SFP-L | RG-S2910-24GT4XS-L | RG-S2910-48GT4XS-L | RG-S2910-24GT4XS-P-L | RG-S2910-24GT4SFP-P-L |
| ²úÆ·³ß´ç£¨¿í×Éî׸ߣ© | 443.0 mm x 268.0 x 44.5 mm (V1.XX/V2.XX) 440 mm x 220 mm x 44 mm (V3.XX¼°ÒÔÉϰ汾) |
443.0 mm x 268.0 mm x 44.5 mm (V1.XX) 440mm x 220mm x 44mm (V2.XX¼°ÒÔÉϰ汾) |
440 mm × 260 mm × 44 mm |
|||
| ²úÆ·ÖØÁ¿ | 3.5 kg (V1.XX/V2.XX) 2.4 kg (V3.XX¼°ÒÔÉϰ汾) |
4.00 kg (V1.XX/V2.XX) 2.83 kg (V3.XX¼°ÒÔÉϰ汾) |
3.50 kg (V1.XX/V2.XX) 2.45 kg (V3.XX¼°ÒÔÉϰ汾) |
4.00 kg (V1.XX) 2.83 kg (V2.XX¼°ÒÔÉϰ汾) |
5.5 kg | 5.5kg |
| »ú¼Ü³ß´ç | 1 RU | |||||
| °²×°·½Ê½ | ×ÀÃæ/±Ú¹Ò/»ú¼Ü/»ú¹ñ | |||||
| ½Ó¿ÚÓëÄ£¿é | RG-S2910-24GT4SFP-L | RG-S2910-48GT4SFP-L | RG-S2910-24GT4XS-L | RG-S2910-48GT4XS-L | RG-S2910-24GT4SFP-P-L | RG-S2910-24GT4XS-P-L |
| ¹Ì»¯ÒµÎñ½Ó¿Ú | 24¸ö10/100/1000Base-T×ÔÊÊÓ¦ÒÔÌ«Íø½Ó¿Ú 4¸ö1GE SFP½Ó¿Ú |
48¸ö10/100/1000Base-T×ÔÊÊÓ¦ÒÔÌ«Íø½Ó¿Ú 4¸ö1GE SFP½Ó¿Ú |
24¸ö10/100/1000Base-T×ÔÊÊÓ¦ÒÔÌ«Íø½Ó¿Ú 4¸ö1GE/10GE SFP+½Ó¿Ú |
48¸ö10/100/1000Base-T×ÔÊÊÓ¦ÒÔÌ«Íø½Ó¿Ú 4¸ö1GE/10GE SFP+½Ó¿Ú |
24¸ö10/100/1000Base-T×ÔÊÊÓ¦ÒÔÌ«Íø½Ó¿Ú 4¸ö1GE SFP½Ó¿Ú |
24¸ö10/100/1000Base-T×ÔÊÊÓ¦ÒÔÌ«Íø½Ó¿Ú 4¸ö1GE/10GE SFP+½Ó¿Ú |
| ¹Ì»¯¹ÜÀí½Ó¿Ú | 1¸öRJ45 Console½Ó¿Ú | |||||
| ½Ó¿ÚÓëÄ£¿é | RG-S2910-24GT4SFP-L | RG-S2910-48GT4SFP-L | RG-S2910-24GT4XS-L | RG-S2910-48GT4XS-L | RG-S2910-24GT4SFP-P-L | RG-S2910-24GT4XS-P-L |
| µçÔ´ | 1¸ö¹Ì»¯µçÔ´ | |||||
| Õû»ú×î´ó¹¦ºÄ | 24W | 40W | 24W | 50W | 40W£¨²»´øPoE¸ºÔØ£© 460W£¨PoEÂúÔØ£© |
|
| ¶î¶¨ÊäÈëµçѹ | 100V AC~240V AC£¬50/60Hz 192V DC~290V DC |
|||||
| ×î´óÊäÈëµçѹ | 90V AC~264V AC£¬50/60Hz | |||||
| ¶î¶¨ÊäÈëµçÁ÷ | 0.6A | 1.5A | 1.5A | 1.5A | 6.8A | 6.8A |
| PoE½Ó¿Ú | ²»Ö§³Ö | ²»Ö§³Ö | ²»Ö§³Ö | ²»Ö§³Ö | ½Ó¿Ú1~24Ö§³ÖPoE/PoE+ (IEEE802.3af/at)¹©µç | |
| PoE¹©µçÏß¶Ô | ²»Éæ¼° | ²»Éæ¼° | ²»Éæ¼° | ²»Éæ¼° | Mode A£¨1-2,3-6Ïß¶Ô£© | |
| PoEÊä³ö¹¦ÂÊ | ²»Éæ¼° | ²»Éæ¼° | ²»Éæ¼° | ²»Éæ¼° | ÿ½Ó¿Ú×î´ó¹©µç30W Õû»ú×î´ó¹©µç370W ˵Ã÷£ºÊµ¼ÊµÄPoE´øÔØÊýÁ¿£¬Çë¸ù¾ÝPoEÊä³ö¹¦Âʼ°PoEÉ豸ʵ¼Ê¹¦ÂʼÆËã¡£ |
|
| »·¾³Óë¿É¿¿ÐÔ | RG-S2910-24GT4SFP-L | RG-S2910-48GT4SFP-L | RG-S2910-24GT4XS-L | RG-S2910-48GT4XS-L | RG-S2910-24GT4SFP-P-L | RG-S2910-24GT4XS-P-L |
| ÏßÀÂÈȲå°Î | Console¿Ú¡¢ÒµÎñ½Ó¿ÚÓëµçÔ´½Ó¿ÚÖ§³Ö | |||||
| ÎÂ¶È | ¹¤×÷ζȣº0°C~50°C ´æ´¢Î¶ȣº-40°C~70°C ˵Ã÷£ºÔÚº£°Î3000Ã×~5000Ã×·¶Î§ÄÚ£¬º£°ÎÿÉý¸ß220Ã×£¬×î¸ßζȹæ¸ñ½µµÍ1¡æ¡£ |
|||||
| ʪ¶È | ¹¤×÷ʪ¶È£º10%RH~90%RH ´æ´¢Êª¶È£º5%RH~95%RH |
|||||
| ·çÉÈ | ÎÞ·çÉÈ | 1¸ö¹Ì»¯·çÉÈ | 1¸ö¹Ì»¯·çÉÈ | 1¸ö¹Ì»¯·çÉÈ | 1¸ö¹Ì»¯·çÉÈ | 1¸ö¹Ì»¯·çÉÈ |
| É¢ÈÈ | ×ÔȻɢÈÈ | ·çÀäÉ¢ÈÈ£¬ÓÒ½ø×ó³ö | ·çÀäÉ¢ÈÈ£¬ÓÒ½ø×ó³ö | ·çÀäÉ¢ÈÈ£¬ÓÒ½ø×ó³ö | ·çÀäÉ¢ÈÈ£¬²à½øºó³ö | ·çÀäÉ¢ÈÈ£¬²à½øºó³ö |
| ÔëÉù | 0dBA | £¼47dBA | £¼45dBA | £¼45dBA | £¼78dBA | £¼78dBA |
| µçÔ´¼à¿Ø | ²»Ö§³Ö | Ö§³Ö¹ÊÕϸ澯 ²»Ö§³ÖÄ£¿é¼à¿Ø£¬ÖÇÄÜÉϵç |
||||
| ·çÉÈ¼à¿Ø | ²»Éæ¼° | Ö§³Ö¹ÊÕϸ澯£¬ÖÇÄܵ÷ËÙ£¨²»Ö§³ÖÊÖ¶¯µ÷ËÙ£© Ö§³Ö·çÉȵ÷ËÙ¼°·çÉȹÊÕϸ澯¹¦ÄÜ |
||||
| ÎÂ¶È¼à¿Ø | Ö§³ÖÎÂ¶È¼à¿Ø£¬Î¶ȸ澯£¬¹ýα£»¤ | |||||
| ·ÀÀ× | 10kV | |||||
| ϵͳ¹æ¸ñ | RG-S2910-24GT4SFP-L | RG-S2910-48GT4SFP-L | RG-S2910-24GT4XS-L | RG-S2910-48GT4XS-L | RG-S2910-24GT4SFP-P-L | RG-S2910-24GT4XS-P-L |
| ½»»»ÈÝÁ¿ | 598Gbps/5.98Tbps | 598Gbps/5.98Tbps | 672Gbps/6.72Tbps | 672Gbps/6.72Tbps | 598Gbps/5.98Tbps | 672Gbps/6.72Tbps |
| °üת·¢ÂÊ | 126Mpps | 166Mpps | 126Mpps | 166Mpps | 126Mpps | 126Mpps |
| Èí¼þ¹æ¸ñ | RG-S2910-24GT4SFP-L RG-S2910-48GT4SFP-L RG-S2910-24GT4XS-L RG-S2910-48GT4XS-L |
RG-S2910-24GT4SFP-P-L RG-S2910-24GT4XS-P-L |
| PoE | ²»Ö§³Ö | ¹©µçÉè¼ÆÖ§³ÖIEEE 802.3af£¨15.4W£©¡¢IEEE 802.3at£¨30W£© Ö§³Ö×Ô¶¯¡¢½ÚÄܹ©µç¹ÜÀíģʽ Ö§³ÖÈÈÆô¶¯²»¼ä¶Ï¹©µç Ö§³Ö¶Ë¿ÚÓÅÏȼ¶ Ö§³Ö¼æÈݷDZê×¼PDÉ豸 Ö§³Ö¶ÔPoE¶Ë¿Ú¶¨Ê±ÉÏϵç |
| MACµØÖ·±í | Ö§³Ö¾²Ì¬MACµØÖ· Ö§³ÖMACµØÖ·¹ýÂË |
|
| 802.1Q VLAN | Ö§³Ö4K 802.1Q VLAN Ö§³ÖPort based VLAN Ö§³ÖMAC based VLAN Ö§³ÖProtocol based VLAN Ö§³ÖPrivate VLAN Ö§³ÖVoice VLAN Ö§³ÖGVRP |
|
| QinQ | Ö§³Ö»ù±¾QinQ Ö§³ÖÁé»îQinQ |
|
| ¶þ²ã»·Íø¼¼Êõ | Ö§³ÖG.8032¹ú¼Ê±ê×¼»·ÍøÐÒéERPS£¬Çл»Ê±¼ä≤50ms£¬¿ÉÓëÆäËûÖ§³Ö¸ÃÐÒéµÄ²úÆ·ÍêÃÀ¼æÈÝ | |
| ¶Ë¿Ú¾ÛºÏ | Ö§³ÖÁ÷Á¿Æ½ºâ·½Ê½ Ö§³ÖLACP¶¯Ì¬¾ÛºÏ Ö§³ÖLACPÓÅÏȼ¶/ÐÉÌ·½Ê½ /×î´ó¿É¾ÛºÏ¿ÚÊýÁ¿ÅäÖà ֧³Ö¿çVSU AP |
|
| Mirror | Ö§³ÖÆÕͨҵÎñ¿Ú¡¢¾ÛºÏ¶Ë¿Ú×÷Ϊ¾µÏñµÄÔ´ÒÔ¼°Ä¿µÄ¶Ë¿Ú Ö§³Ö»ùÓÚÁ÷¡¢»ùÓÚVLANµÄ¶Ë¿Ú¾µÏñ Ö§³ÖÒ»¶ÔÒ»¡¢RSPAN Ö§³Ö¿çÉ豸µÄÁ÷Á¿¾µÏñ |
|
| DHCP | Ö§³ÖDHCP Server Ö§³ÖDHCP Client Ö§³ÖDHCP Snooping Ö§³ÖDHCP Relay |
|
| VSUÌØÐÔ | Ö§³ÖVSUÐéÄ⻯¼¼Êõ Ö§³Ö±¾µØ¶ÑµþºÍÔ¶³Ì¶Ñµþ Ö§³Öͨ¹ý±ê×¼ÒµÎñ¿ÚʵÏÖÐéÄ⻯ |
|
| IP·ÓÉ | IPv4/IPv6¾²Ì¬Â·ÓÉ¡¢¿ÉÀ©Õ¹Ö§³ÖRIP¡¢RIPng¡¢OSPF¡¢OSPFv3ÐÒé | |
| ACL | Ö§³Ö±ê×¼IP ACL£¨»ùÓÚIPµØÖ·µÄÓ²¼þACL£© Ö§³ÖÀ©Õ¹IP ACL£¨»ùÓÚIPµØÖ·¡¢TCP/UDP¶Ë¿ÚºÅµÄÓ²¼þACL£© Ö§³ÖMACÀ©Õ¹ACL£¨»ùÓÚÔ´MACµØÖ·¡¢Ä¿µÄMACµØÖ·ºÍ¿ÉÑ¡µÄÒÔÌ«ÍøÀàÐ͵ÄÓ²¼þACL£© Ö§³Ö»ùÓÚʱ¼äACL Ö§³ÖACL80 Ö§³ÖÈ«¾ÖACL Ö§³ÖACLÖØ¶¨Ïò |
|
| QoS | Ö§³Ö¶Ë¿ÚÁ÷Á¿Ê¶±ð Ö§³Ö¶Ë¿ÚÁ÷Á¿ÏÞËÙ Ö§³Ö802.1p/DSCP/TOSÁ÷Á¿·ÖÀà ÿ¶Ë¿Ú8¸öÓÅÏȼ¶¶ÓÁÐ Ö§³ÖSP¡¢WRR¡¢DRR¡¢SP+WFQ¡¢ SP+WRR¡¢SP+DRR¡¢RED/WRED¶ÓÁе÷¶È |
|
| °²È«ÌØÐÔ | ¹ýÂË·Ç·¨µÄMACµØÖ· Ö§³Ö¹ã²¥·ç±©ÒÖÖÆ ¹ÜÀíÔ±·Ö¼¶¹ÜÀíºÍ¿ÚÁî±£»¤ Ö§³ÖRADIUS ºÍ TACACS+ Ö§³ÖSSH ºÍ SSH V2.0 Ö§³ÖBPDU Guard Ö§³ÖCPP¡¢NFPP Ö§³Ö¶Ë¿Ú±£»¤ |
|
| EEE | Ö§³ÖIEEE 802.3az±ê×¼µÄEEE£¨Energy Efficient Ethernet£¬½ÚÄÜÒÔÌ«Íø£©¼¼Êõ | |
| ¹ÜÀíÌØÐÔ | SNMP¡¢CLI(Telnet/Console)¡¢RMON¡¢SSH¡¢Syslog/Debug¡¢NTP/SNTP¡¢FTP¡¢TFTP¡¢Web¡¢WIS¹«ÓÐÔÆÆ½Ì¨¹ÜÀí | |
¿ÉÒԵģ¬RG-S2910-24GT4SFP-LÕâ¿î½»»»»ú²ÉÓÃÎÞ·çÉÈÉè¼Æ£¬×ÔȻɢÈÈ£¬ÎÞÔëÒô£¬¼´Ê¹Àë°ì¹«ÊҺܽüÒ²²»Óõ£ÐÄÔëÒôÎÊÌ⣻ͬʱËü»¹Ö§³Ö¸ßЧ½ÚÄÜÒÔÌ«Íø£¨EEE£©£¬¶Ë¿Ú×Ô¶¯ÐÝÃߣ¬½ÚÊ¡É豸Äܺġ£
ÕâЩ¶¼ÊÇÖ§³ÖµÄ£¬ÏêϸÄÚÈÝÒ²¿ÉÒԲ鿴֧³ÖµÄÈí¼þÐÒé°å¿éºÍ²úÆ·²ÊÒ³¡£