¹«º£²Ê´¬¡¤6600(ÖйúÓÎ)¹Ù·½ÍøÕ¾

µã»÷ÏÂÔØ¡¶ÍòÕ×Ô°ÇøÒÔÌ«²Ê¹âÑо¿±¨¸æ¡·£¬½âËøÍòÕ×Ô°ÇøÍøÂ罨ÉèÖ¸ÄÏ
Á¢¼´ÏÂÔØ
ÎÞ¸Ð×¼Èë ÈËÎïͳ¹Ü Ø­ RG-SAM+5.X ÐÂÒ»´ú¸ßУAIÈÏ֤ƽ̨·¢²¼
Ô¤Ô¼Ö±²¥
²úÆ·
< ·µ»ØÖ÷²Ëµ¥
²úÆ·ÖÐÐÄ
²úÆ·
ºÏ×÷»ï°é
·µ»ØÖ÷²Ëµ¥
Ñ¡ÔñÇøÓò/ÓïÑÔ
RG-S2910-24GT4XS-UP-H
RG-S2910-24GT4XS-UP-H
RG-S2910-24GT4XS-UP-H
RG-S2910-24GT4XS-UP-H
RG-S2910-24GT4XS-UP-H
RG-S2910-24GT4XS-UP-H
¼ÓÔØÖÐ...0%
ͼƬ

24¿ÚǧÕ×µç½ÓÈë½»»»»ú£¬4¸öÍòÕ×ÉÏÐпڣ¬RG-S2910-24GT4XS-UP-H

ÖÇÄܽ¨Öþ³¡¾°Öи÷ÖÖϵͳ´ó¹¦ÂÊÖն˵ÄPoEÔ¶³Ì¹©µç£»¸÷ÖÖÊÒÍâÎÞÏß²¿Ê𳡾°£¬Âú×ãÊÒÍâ´ó¹¦ÂÊÎÞÏß½ÓÈëµãµÄ¹©µçÐèÇó

²úÆ·ÌØÐÔ£º

  • ´ó¹¦ÂÊÔ¶³Ì¹©µç£¬ÈÃÄÜÁ¿´©¹ýÍøÂç
  • ÍøÏßµçÏߺÏÒ»£¬²¿Êð¼òµ¥
  • ´ÓÉ豸µ½¹©µç¡¢ÔÙµ½ÍøÂ磬ÈýάһÌå±£Õϰ²È«Îȶ¨
  • Ô¶³ÌÖØÆô£¬ÇáËÉÔËά
Á¢¼´×Éѯ

²úÆ·¸ÅÊö

RG-S2910-HϵÁн»»»»úÊǹ«º£²Ê´¬¡¤6600ÍøÂçÃæÏò°²È«¡¢¸ßЧºÍ½ÚÄܵÄÉè¼ÆÀíÄîÍÆ³öµÄÐÂÒ»´úǧÕ×ÒÔÌ«Íø½»»»»ú£¬¿ÉÌṩȫǧÕ×½ÓÈëºÍÁé»îÀ©Õ¹µÄÍòÕ×ÉÏÐÐÊý¾Ý½»»¥ÄÜÁ¦¡£¸ÃϵÁвúÆ·²ÉÓÃȫеÄÓ²¼þ¼Ü¹¹Éè¼Æ£¬´îÔØ¹«º£²Ê´¬¡¤6600ÍøÂç×îеÄRGOS11.XÄ£¿é»¯²Ù×÷ϵͳ£¬¿ÉÌṩ¸ü´óµÄ×ÊÔ´±íÏî¡¢¸ü¿ìµÄÓ²¼þ´¦ÀíÐÔÄÜ¡¢¸ü¸ßµÄ²Ù×÷ʹÓÃÌåÑé¡£³ä·ÖÂú×ãÓû§¸ßÃܶȽÓÈëµÄÐèÇ󣬲»Í¬ÅäÖõÄPoE»úÐÍ»¹¿ÉÂú×ãÕû»úËùÓÐÏÂÐж˿ÚPoE+¸ºÔصĽÓÈëÐèÇóºÍÍòÕ×ÉÏÁªµÄ¸ß´ø¿íÐèÇó¡£

²úÆ·ÌØÐÔ

ÍøÂ簲ȫ

Ö§³Ö¸÷ÖÖÀàÐÍACL¡¢¶Ë¿Ú°²È«¡¢IP+MAC+Port°ó¶¨µÈ¼¼Êõ£¬Äܹ»ÓÐЧ·ÀÖ¹¸÷ÖÖARPÆÛÆ­£¬²¢ÇҾ߱¸Ö÷¶¯·À»¤¸÷ÖÖDoS¡¢DDoS¹¥»÷µÄÄÜÁ¦¡£

Ö§³Ö¹«º£²Ê´¬¡¤6600ÍøÂçÌØÓеÄCPU±£»¤²ßÂÔ£¨CPP£¬CPU Protect Policy£©ºÍ»ù´¡ÍøÂç±£»¤²ßÂÔ£¨NFPP£¬Network Foundation Protection Policy£©£¬¿É¶Ô·¢ÍùCPUµÄÊý¾ÝÁ÷£¬½øÐÐÁ÷Çø·ÖºÍÓÅÏȼ¶¶ÓÁзּ¶´¦Àí£¬²¢¸ù¾ÝÐèҪʵʱ´ø¿íÏÞËÙ£¬³ä·Ö±£»¤CPU²»±»·Ç·¨Á÷Á¿Õ¼ÓᢶñÒâ¹¥»÷ºÍ×ÊÔ´ÏûºÄ£¬±£ÕÏÁËCPUÎȶ¨ÔËÐС£Í¬Ê±£¬Äܹ»ÏÞÖÆÓû§ÏòÍøÂçÖз¢ËÍARP±¨ÎÄ¡¢ICMPÇëÇó±¨ÎÄ¡¢DHCPÇëÇó±¨ÎĵÈÊý¾Ý°üµÄÊýÂÊ£¬¶Ô³¬¹ýÏÞËÙãÐÖµµÄ±¨ÎĽøÐжªÆú´¦Àí£¬ÉõÖÁÄܹ»Ê¶±ð¹¥»÷ÐÐΪ£¬¶ÔÓй¥»÷ÐÐΪµÄÓû§½øÐиôÀ룬±£Ö¤É豸ºÍÕûÍøµÄ°²È«Îȶ¨ÔËÐС£

Ö§³Ö¿ìËÙÁ´Â·¼ì²âЭÒ飨RLDP£¬Rapid Link Detection Protocol£©£¬¿É¿ìËÙ¼ì²âÁ´Â·µÄͨ¶ÏºÍ¹âÏËÁ´Â·µÄµ¥ÏòÐÔ£¬²¢Ö§³Ö¶Ë¿ÚÏµĻ·Â·¼ì²â¹¦ÄÜ£¬·ÀÖ¹¶Ë¿ÚÏÂÒò˽½ÓHubµÈÉ豸ÐγɵĻ·Â·¶øµ¼ÖÂÍøÂç¹ÊÕϵÄÏÖÏó

ÐéÄâ½»»»µ¥Ôª£¨VSU£¬Virtual Switching Unit£©

RG-S2910-HϵÁвúÆ·Ö§³ÖÐéÄâ½»»»µ¥Ôª£¨VSU£¬Virtual Switching Unit£©¡£Äܹ»½«¶ą̀ÎïÀíÉ豸½øÐл¥Áª£¬Ê¹ÆäÐéÄâΪһ̨Âß¼­É豸£¬ÀûÓõ¥Ò»IPµØÖ·¡¢µ¥Ò»Telnet½ø³Ì¡¢µ¥Ò»ÃüÁîÐнӿÚ(CLI)¡¢×Ô¶¯°æ±¾¼ì²é¡¢×Ô¶¯ÅäÖõÈÌØÐÔ½øÐйÜÀí£¬¶ÔÓû§À´Ëµ½ö½öÊÇÔÚ¹ÜÀíһ̨É豸£¬µ«ÊÇȴʵÏÖ×Ŷą̀É豸´øÀ´µÄ¹¤×÷ЧÂʺÍʹÓÃÌåÑé¡£

¼ò»¯¹ÜÀí£º¹ÜÀíÔ±¿ÉÒÔ¶Ô¶ą̀½»»»»úͳһ¹ÜÀí£¬¶ø²»ÐèÒªÁ¬½Óµ½Ã¿Ì¨½»»»»ú·Ö±ð½øÐÐÅäÖú͹ÜÀí¡£

¼ò»¯ÍøÂçÍØÆË£ºVSUÔÚÍøÂçÖÐÏ൱ÓÚһ̨½»»»»ú£¬Í¨¹ý¾ÛºÏÁ´Â·ºÍÍâΧÉ豸Á¬½Ó£¬²»´æÔÚ¶þ²ã»·Â·£¬Ã»±ØÒªÅäÖÃMSTPЭÒ飬¸÷ÖÖ¿ØÖÆÐ­ÒéÊÇ×÷Ϊһ̨½»»»»úÔËÐеÄ¡£

ºÁÃë¼¶¹ÊÕϻָ´£ºVSUºÍÍâΧÉ豸ͨ¹ý¾ÛºÏÁ´Â·Á¬½Ó£¬Èç¹ûÆäÖÐһ̨É豸»òÕßÒ»Ìõ³ÉÔ±Á´Â·³öÏÖ¹ÊÕÏ£¬Çл»µ½ÁíÒ»Ìõ³ÉÔ±Á´Â·µÄʱ¼äÖ»ÐèÒª50µ½200ºÁÃë¡£

¸ßÀ©Õ¹ÐÔ£ºÓû§ÐÂÔöµÄÉ豸¼ÓÈë»òÀ뿪ÐéÄâ»¯ÍøÂçʱ¿ÉÒÔʵÏÖ¡°ÈȲå°Î¡±£¬²»Ó°ÏìÆäËûÉ豸µÄÕý³£ÔËÐС£

±£»¤Í¶×Ê£ºVSUºÍÍâΧÉ豸ͨ¹ý¾ÛºÏÁ´Â·Á¬½Ó£¬¼ÈÌṩÁËÈßÓàÁ´Â·£¬ÓÖ¿ÉÒÔʵÏÖ¸ºÔؾùºâ£¬³ä·ÖÀûÓÃËùÓÐÍøÂçÉ豸ºÍ´ø¿í×ÊÔ´¡£Í¬Ê±¿ÉÓÃÈÎÒâÐÎ̬µÄÍòÕ×¶Ë¿Úͨ¹ýÈÎÒâµÄÊý¾Ý´«ÊäÏßÀÂ×é³ÉVSUÐéÄâÍøÂçϵͳ£¬²»ÐèÒª¶îÍâÅäÖÃÏßÀ¡¢À©Õ¹¿¨£¬²¢ÇÒûÓж˿ںÍÏßÀÂÖÖÀàµÄÏÞÖÆ£¬×î´óÏ޶ȱ£»¤Óû§µÄͶ×Ê¡£

±ê׼ЭÒ飬É豸¶Ô½Ó¸üÈÝÒ×

Ö§¹«ÓÐÒÔÌ«Íø¶à»·±£»¤¼¼Êõ£¨ERPS£©£¬¹ú¼Ê±ê׼ΪºËÐÄÒÔÌ«ÍøÉè¼ÆµÄ¶þ²ãÁ´Â·ÈßÓ౸·ÝЭÒ飬Æä»·Â·×è¶ÏÒÔ¼°Á´Â·»Ö¸´¶¼¼¯ÖÐÔÚÖ÷¿ØÉ豸ÉϽøÐУ¬·ÇÖ÷¿ØÉ豸ֱ½ÓÏòÖ÷¿ØÉ豸»ã±¨×Ô¼ºµÄÁ´Â·Çé¿ö£¬ÎÞÐè¾­¹ýÆäËû·ÇÖ÷¿ØÉ豸µÄ´¦Àí£¬Òò´Ë»·Â·ÖжÏÒÔ¼°»Ö¸´Ê±¼ä±ÈSTP¿ì¡£»ùÓÚÒÔÉÏÇø±ð£¬ERPSÔÚÀíÏë»·¾³ÏµÄÁ´Â·»Ö¸´ÄÜÁ¦Äܹ»´ïµ½ºÁÃë¼¶¡£

¼òµ¥ÇáËɵÄÍøÂçά»¤

Ö§³ÖSNMP¡¢RMON¡¢Syslog¡¢sFLOWµÈÌØÐÔÀ´½øÐÐÍøÂçµÄÈÕ³£Õï¶Ï¼°Î¬»¤£¬Í¬Ê±¹ÜÀíÔ±¿É²ÉÓÃCLI¡¢WebÍø¹Ü¡¢Telnet¡¢CWMP(TR069)ÁãÅäÖõȶàÑù»¯µÄ¹ÜÀíºÍά»¤·½Ê½¸ü·½±ãÉ豸µÄ¹ÜÀí¡£

PoEʹÓÃ״̬һĿÁËÈ»£ºÃæ°å×Ô´øÒ»¼ü²é¿´PoE¹©µç״̬¹¦ÄܵÄPoE°´Å¥£¬Çá°´¼´¿É²é¿´É豸µ±Ç°µÄͨÐÅ״̬ºÍ¹©µç״̬£¬ÈÃÄú¶ÔËùÓж˿ÚPoE¹©µçµÄ״̬ÁËÈ»ÓÚÐÄ¡£

Ö§³Ö»ùÓÚSNMP¡¢ERSPAN¡¢NetconfµÈ¼¼ÊõµÄTelemetry£¬ÊµÏÖ¶Ô½»»»»úÔËÐÐ״̬ÐÅÏ¢µÄ²É¼¯¡£

¼¼Êõ²ÎÊý

Ó²¼þ¹æ¸ñ

Ó²¼þ¹æ¸ñ RG-S2910-24GT4SFP-UP-H RG-S2910-24GT4XS-UP-H
½Ó¿Ú¹æ¸ñ
¹Ì»¯ÒµÎñ½Ó¿Ú 24¸ö10/100/1000M×ÔÊÊÓ¦µç¿Ú£¬4¸öǧÕ×SFP¹â¿Ú 24¸ö10/100/1000M×ÔÊÊÓ¦µç¿Ú£¬4¸ö1G/10G SFP+¹â¿Ú
ϵͳ¹æ¸ñ
½»»»ÈÝÁ¿ 672Gbps/6.72Tbps 672Gbps/6.72Tbps
°üת·¢ÂÊ 126Mpps 171Mpps
³ß´çÓëÖØÁ¿
²úÆ·³ß´ç£¨¿í¡ÁÉî¡Á¸ß£© V6.XX¼°ÒÔϰ汾£º440mm x 260mm x 44mm
V7.XX°æ±¾£º440mm x 220mm x 43.6mm
V4.XX¼°ÒÔϰ汾£º440mm x 260mm x 44mm
V5.XX°æ±¾£º440mm x 220mm x 43.6mm
²úÆ·ÖØÁ¿ V6.XX¼°ÒÔϰ汾£º5.5 kg£¨º¬°ü×°£©
V7.XX°æ±¾£º2.85 kg
V4.XX¼°ÒÔϰ汾£º5.5 kg£¨º¬°ü×°£©
V5.XX°æ±¾£º2.85 kg
µçÔ´Ó빦ºÄ
µçÔ´ÊäÈë
  • V6.XX¼°ÒÔϰ汾

½»Á÷£¨AC£©ÊäÈ룺
¶î¶¨µçѹ·¶Î§100V~240V£¬ÆµÂÊ50/60Hz
×î´óµçѹ·¶Î§90V~264V£¬ÆµÂÊ50/60Hz
¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺
ÊäÈëµçѹ·¶Î§192V~290V
  • V7.XX°æ±¾

½»Á÷£¨AC£©ÊäÈ룺
¶î¶¨µçѹ·¶Î§100V~240V£¬ÆµÂÊ50/60Hz
×î´óµçѹ·¶Î§90V~290V£¬ÆµÂÊ50/60Hz
¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺
ÊäÈëµçѹ·¶Î§190V~290V
  • V4.XX¼°ÒÔϰ汾

½»Á÷£¨AC£©ÊäÈ룺
¶î¶¨µçѹ·¶Î§100V~240V£¬ÆµÂÊ50/60Hz
×î´óµçѹ·¶Î§90V~264V£¬ÆµÂÊ50/60Hz
¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺
ÊäÈëµçѹ·¶Î§192V~290V
  • V5.XX°æ±¾

½»Á÷£¨AC£©ÊäÈ룺
¶î¶¨µçѹ·¶Î§100V~240V£¬ÆµÂÊ50/60Hz
×î´óµçѹ·¶Î§90V~290V£¬ÆµÂÊ50/60Hz
¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺
ÊäÈëµçѹ·¶Î§190V~290V
PoE¹©µç±ê×¼ 24¸öµç¿ÚÖ§³ÖPoEºÍPoE+ 24¸öµç¿ÚÖ§³ÖPoEºÍPoE+
Õû»ú×î´ó¹¦ºÄ 40W£¨²»´øPoE¸ºÔØ£©
460W£¨PoEÂúÔØ£©
40W£¨²»´øPoE¸ºÔØ£©
460W£¨PoEÂúÔØ£©
»·¾³Óë¿É¿¿ÐÔ
·çÉÈ¼à¿Ø Ö§³Ö·çÉȵ÷ËÙ¼°·çÉȹÊÕϸ澯¹¦ÄÜ
¹¤×÷ÎÂ¶È 0¡æ~50¡æ
´æ´¢ÎÂ¶È -40¡æ~70¡æ
¹¤×÷ʪ¶È 10%~90%RH
´æ´¢Êª¶È 5%~95%RH
¹¤×÷º£°Î -500m~5000m
·ÀÀ× 10kV

Èí¼þ¹æ¸ñ

Èí¼þ¹æ¸ñ RG-S2910-24GT4SFP-UP-H RG-S2910-24GT4XS-UP-H
VLAN Ö§³Ö4K VLAN
Ö§³ÖPort based VLAN
Ö§³ÖMAC based VLAN
Ö§³ÖProtocol based VLAN
Ö§³ÖPrivate VLAN
Ö§³ÖVoice VLAN
Ö§³ÖIP subnet-based VLAN
Ö§³ÖGVRP
QinQ Ö§³Ö»ù±¾QinQ
Ö§³ÖÁé»îQinQ
ACL Ö§³ÖIP±ê×¼IP ACL
Ö§³ÖIPÀ©Õ¹IP ACL
Ö§³ÖMACÀ©Õ¹ACL£¨»ùÓÚÔ´MACµØÖ·¡¢Ä¿µÄMACµØÖ·ºÍ¿ÉÑ¡µÄÒÔÌ«ÍøÀàÐ͵ÄÓ²¼þACL£©
Ö§³Ö»ùÓÚʱ¼äACL
Ö§³Öר¼Ò¼¶ACL£¨¿Éͬʱ»ùÓÚVLANºÅ¡¢ÒÔÌ«ÍøÀàÐÍ¡¢MACµØÖ·¡¢IPµØÖ·¡¢TCP/UDP¶Ë¿ÚºÅ¡¢Ð­ÒéÀàÐÍ¡¢Ê±¼äµÈÁé»î×éºÏµÄÓ²¼þACL£©
Ö§³ÖACL80
Ö§³ÖIPv6 ACL
Ö§³ÖÈ«¾ÖACL
Ö§³ÖACLÖØ¶¨Ïò
QoS Ö§³Ö»ùÓÚÈë¿Ú/³ö¿ÚµÄ¶Ë¿ÚÏÞËÙ
Ö§³ÖÈë¿Ú/³ö¿Ú»ùÓÚÁ÷µÄÏÞËÙ
Ö§³Ö802.1p/DSCP/ToSÁ÷Á¿·ÖÀà
ÿ¶Ë¿Ú8¸öÓÅÏȼ¶¶ÓÁÐ
Ö§³ÖSP¡¢WRR¡¢DRR¡¢SP+WFQ¡¢SP+WRR¡¢SP+DRR¡¢RED/WRED¶ÓÁе÷¶È
Mirror Ö§³ÖÆÕͨҵÎñ¿Ú¡¢¾ÛºÏ¶Ë¿Ú×÷Ϊ¾µÏñµÄÔ´ÒÔ¼°Ä¿µÄ¶Ë¿Ú
Ö§³ÖÒ»¶ÔÒ»¡¢Ò»¶Ô¶à¡¢¶à¶ÔÒ»ºÍ»ùÓÚÁ÷µÄ±¾µØ¡¢Ô¶³Ì¾µÏñ
Ö§³ÖRSPAN¡¢ERSPAN
Ö§³Ö¿çÉ豸µÄÁ÷Á¿¾µÏñ
DHCP Ö§³ÖDHCP Server
Ö§³ÖDHCP Client
Ö§³ÖDHCP Snooping
Ö§³ÖDHCP Relay
Ö§³ÖIPv6 DHCP Snooping
Ö§³ÖIPv6 DHCP Client
Ö§³ÖIPv6 DHCP Relay
L2 ЭÒé IEEE 802.3¡¢IEEE 802.3u¡¢IEEE 802.3z ¡¢IEEE 802.3x¡¢IEEE 802.3ad¡¢IEEE 802.1p¡¢IEEE 802.1x¡¢IEEE 802.3ab¡¢IEEE 802.1Q (GVRP)¡¢IEEE 802.1d¡¢IEEE 802.1w¡¢IEEE 802.1s¡¢IGMP Snooping v1/v2
°²È«ÌØÐÔ Ö§³ÖIP¡¢MAC¡¢¶Ë¿ÚÈýÔªËØ°ó¶¨
Ö§³ÖIPv6¡¢MAC¡¢¶Ë¿ÚÈýÔªËØ°ó¶¨
¹ýÂË·Ç·¨µÄMACµØÖ·
Ö§³Ö»ùÓڶ˿ںÍMACµÄ802.1x
Ö§³ÖMAB
Ö§³ÖPortal ºÍPortal2.0ÈÏÖ¤
Ö§³ÖARP-Check
Ö§³ÖDAI
Ö§³Ö¿ÉÐÅÈÎARP
Ö§³Ö·ÀÍø¹ØARPÆÛÆ­
Ö§³Ö¹ã²¥/¶à²¥·ç±©ÒÖÖÆ
Ö§³Öδ֪Ãûµ¥²¥ÒÖÖÆ£¬×é²¥´ø¿íÒÖÖÆ
¹ÜÀíÔ±·Ö¼¶¹ÜÀíºÍ¿ÚÁî±£»¤
Ö§³ÖRADIUSºÍTACACS+
É豸µÇ½¹ÜÀíµÄAAA°²È«ÈÏÖ¤£¨IPv4/IPv6£©
Ö§³ÖSSH ºÍ SSH V2.0
Ö§³ÖBPDU Guard
Ö§³ÖIP Source Guard
Ö§³ÖCPP¡¢NFPP
Ö§³Ö¶Ë¿Ú±£»¤
ÏßÀ¼ì²â Ö§³ÖÏßÀ¼ì²â
EEE Ö§³ÖIEEE 802.3az ±ê×¼µÄ EEE½ÚÄܼ¼Êõ£ºµ±EEEʹÄÜʱ£¬´Ó¶ø´ó·ù¶ÈµÄ¼õС¶Ë¿ÚÔڸý׶εŦºÄ£¬´ïµ½Á˽ÚÄܵÄÄ¿µÄ¡£
¶Ë¿ÚÐÝÃß Ö§³Ö¶Ë¿ÚÐÝÃß
PoE ¹©µçÉè¼ÆÖ§³ÖIEEE 802.3af¡¢IEEE 802.3at
Ö§³Ö×Ô¶¯¡¢½ÚÄܹ©µç¹ÜÀíģʽ
Ö§³ÖÈÈÆô¶¯²»¼ä¶Ï¹©µç
Ö§³Ö¶Ë¿ÚÓÅÏȼ¶
Ö§³Ö¼æÈݷDZê×¼PDÉ豸
Ö§³Ö¶ÔPoE¶Ë¿Ú¶¨Ê±ÉÏϵç
IP·ÓÉ IPv4/IPv6 ¾²Ì¬Â·ÓÉ
RIP¡¢RIPng¡¢OSPFv2¡¢OSPFv3
Routing Policy
IPv6
»ù´¡Ð­Òé
IPv6±àÖ·¡¢ÁÚ¾Ó·¢ÏÖЭÒ飨ND£©¡¢IPv6 ACL¡¢ICMPv6¡¢IPv6 Ping¡¢IPv6 TracertµÈ
VSUÌØÐÔ Ö§³ÖVSUÐéÄ⻯¼¼Êõ
Ö§³Ö±¾µØ¶ÑµþºÍÔ¶³Ì¶Ñµþ
Ö§³Ö¶ÑµþÄÚ¿ç»úÏäµÄÁ´Â·À¦°ó
ÁãÅäÖà ֧³ÖCWMP(TR069)ЭÒé±ê׼ЭÒé
¹ÜÀíÌØÐÔ SNMP¡¢CLI(Telnet/Console)¡¢RMON¡¢SSH¡¢Syslog/Debug¡¢NTP/SNTP¡¢FTP¡¢TFTP¡¢Web¡¢sFLOW
Õ¹¿ªÏêϸ²ÎÊý

×ÊÔ´ÖÐÐÄ

ÓªÏú×ÊÁÏ
Ó¦Óð¸Àý
¼¼Êõ²©ÎÄ
ÊÛºóÎĵµ

³£¼ûÎÊÌâ

ÎÒÒªÌáÎÊ
È«²¿
¹¦ºÄ(1)
µçÔ´(2)
Èý²ã½»»»»ú(1)
ÃüÃû¹æÔò(1)
¶Ë¿Ú¾ÛºÏ(1)
»·Â·¼ì²â(1)
¹«º£²Ê´¬¡¤6600 2022Äê07ÔÂ25ÈÕ
¸Ã¿î½»»»»úÊǼ¸²ã½»»»»ú£¿
ÓÐÓÃ 138 ÎÞÓÃ 19

Èý²ãµÄ£¬RG-S2910XS-E¡¢RG-S2910-H¡¢RG-S2910G-P¡¢RG-S2910V2¡¢RG-S2910-LµÈϵÁн»»»»ú¶¼ÊÇÈý²ã½»»»»ú¡£

¹«º£²Ê´¬¡¤6600 2022Äê07ÔÂ25ÈÕ
RG-S2910-24GT4SFP-UP-H¡¢RG-S2910-24GT4XS-UP-H¡¢RG-S2910C-48GT2XS-P-E¡¢RG-S2910-48GT4XS-EÊÇ·ñÖ§³ÖµçÔ´ÈßÓࣿ
ÓÐÓÃ 72 ÎÞÓÃ 5

RG-S2910C-48GT2XS-HP-E½»»»»úµçÔ´Ö§³ÖÁ½¸öµçÔ´Ä£¿é¹¤×÷£¬Èç¹ûµ¥µçÔ´Ä£¿é¹¦ÂÊ´óÓÚ¹¤×÷¹¦ÂÊÔò¿ÉÒÔÈßÓ࣬ÆäËûÈý¿î²»Ö§³ÖÈßÓà¡£

Õ¹¿ªÈ«²¿
Èç¹ûÄúÐèÒª¸ü¶à²úÆ·¼¼Êõ×Éѯ
¾ßÌåÐÔÄÜÄÜ·ñÂú×ãÄúµÄÒµÎñ·åÖµ£¿ÈçºÎ¹æ»®²¿ÊðÓëÅäÖã¿
Á¢¼´×Éѯ

·µ»Ø¶¥²¿

ÊÕÆð
ÎĵµAIÖúÊÖ
ÎĵµÆÀ¼Û
¸Ã×ÊÁÏÊÇ·ñ½â¾öÁËÄúµÄÎÊÌ⣿
Äú¶Ôµ±Ç°Ò³ÃæµÄÂúÒâ¶ÈÈçºÎ£¿
²»Õ¦µÎ
·Ç³£ºÃ
ÄúÂúÒâµÄÔ­ÒòÊÇ£¨¶àÑ¡£©£¿
Äú¶ÔÎĵµÊÇ·ñ»¹ÓÐÆäËüµÄÎÊÌâ»ò½¨Ò飿
Ϊ¾¡¿ì½â¾öÎÊÌ⣬ÇëÄúÁôÏÂÁªÏµ·½Ê½Òﱋȯ¸´
ÓÊÏä
ÊÖ»úºÅ
¸ÐлÄúµÄ·´À¡£¡
ÇëÑ¡Ôñ·þÎñÏîÄ¿
¹Ø±Õ×Éѯҳ
ÊÛǰ×Éѯ ÊÛǰ×Éѯ
ÊÛǰ×Éѯ
ÊÛºó·þÎñ ÊÛºó·þÎñ
ÊÛºó·þÎñ
Òâ¼û·´À¡ Òâ¼û·´À¡
Òâ¼û·´À¡
¸ü¶àÁªÏµ·½Ê½
¡¾ÍøÕ¾µØÍ¼¡¿¡¾sitemap¡¿