    ͼƬ

    48¿ÚǧÕ×µç½ÓÈë½»»»»ú£¬4¸öÍòÕ×ÉÏÐпÚ£¬RG-S2910-48GT4XS-E

    ´óÐÍÆóÊÂÒµÔ°ÇøÄÚ¾ÖÓòÍøµÄȫǧÕ×½ÓÈ룬ÉÌҵϵͳµÄǧÕ×½ÓÈë

    ²úÆ·ÌØÐÔ£º

    • ÂÌÉ«½ÚÄÜ£¬±Èͬµµ²úÆ·½ÚÊ¡¹¦ºÄ40%
    • ´îÔØ¹«º£²Ê´¬¡¤6600ÍøÂç×ÔÑÐ¶à½ø³ÌÄ£¿é»¯RGOS11.X²Ù×÷ϵͳ
    • Ö§³ÖSDNÌØÐÔ£¬·ûºÏOpenflow1.3ЭÒé±ê×¼
    • Ö§³ÖTR069ÁãÅäÖÃÉÏÏߣ»·á¸»¶àÑùµÄ¶Ë¿ÚÐÎ̬ѡÔñ
    Á¢¼´×Éѯ

    Áé»îµÄÀ©Õ¹ÐÔÄÜ

    RG-S2910XS-EϵÁвúÆ·µÄËùÓеÄSFP+ºÍSFP¶Ë¿Ú¾ù¿ÉÒÔÏòϼæÈݵÍÒ»¼¶µÄ¹â½Ó¿ÚÄ£¿é£»PoEÐͺÅÖ§³Ö±ê×¼µÄ802.3afºÍ802.3atÔ¶³Ì¹©µç±ê×¼£¬ÌṩÄ£¿é»¯Ë«µçÔ´£¬Äܹ»Ö§³ÖËùÓÐÏÂÐж˿ÚPoE+Âú¸ºÔع©µç£»Í¬Ê±Å䱸ÊýÁ¿²»µÈµÄÀ©Õ¹²Û룬¿É¸ù¾ÝÓû§ÐèÒªÁé»îÀ©Õ¹²»Í¬ÊýÁ¿µÄÍòÕ×¹â¿Ú£¬¸ù¾ÝÓû§µÄʹÓó¡¾°Á¿Éí¶¨ÖÆ×¨ÊôµÄÅäÖá£

    ÍêÉÆµÄ°²È«·À»¤²ßÂÔ

    ARP²¡¶¾»ò¹¥»÷ÊÇÍøÂçÖг£¼û£¬Í¬Ê±Ó°Ïì½Ï´óµÄÒ»À๥»÷¡£RG-S2910XS-EϵÁн»»»»úÖ§³Ö¶àÖÖģʽµÄARP·ÀÆÛÆ­¹¦ÄÜ£¬²»ÂÛÊÇÓû§Í¨¹ýDHCP·þÎñÆ÷×Ô¶¯»ñÈ¡µØÖ·£¬»¹ÊÇʹÓù̶¨µÄIPµØÖ·£¬RG-S2910XS-EϵÁÐÄܹ»¼Ç¼Óû§ÕæÊµµÄIP+MACµØÖ·£¬²¢ÔÚ½»»»»ú¶Ë¿ÚÊÕµ½Ö÷»ú·¢Ë͵ÄARP±¨ÎÄʱ£¬½«ARP±¨ÎÄÄÚÈݺͼǼµÄIP+MACµØÖ·½øÐбȶÔ£¬Ö»¶ÔÄÚÈÝÕæÊµµÄARP±¨ÎĽøÐÐת·¢£¬¶ÔÐé¼ÙµÄARP±¨ÎĽøÐжªÆú£¬´Ó¶ø½«ARPÆÛÆ­ÆÁ±ÎÔÚÍøÂçÖ®Í⣬±£ÕÏÍøÂçÓû§ÃâÊÜARP²¡¶¾¹¥»÷¡£

    Ö÷¶¯·ÀÓùÍøÂçÖеĸ÷ÖÖDDOS¹¥»÷£¬ÍøÂçÓÉÓÚÆä¿ª·ÅÐÔ£¬¾­³£ÓÉÓÚ¼ÆËã»ú¸ÐȾ²¡¶¾£¬»òÊǽÓÈëÍøÂçµÄÈËÔ±³öÓÚ¸÷ÖÖÄ¿µÄ¶ÔÍøÂçÉ豸¡¢ÍøÂçÖеķþÎñÆ÷½øÐй¥»÷£¬µ¼ÖÂÍøÂçÎÞ·¨Õý³£Ê¹Ó᣽ϳ£¼ûµÄÈçARP·ººé¹¥»÷µ¼ÖÂÍø¹ØÎÞ·¨ÏìÓ¦ÇëÇó¡¢ICMP·ººé¹¥»÷µ¼ÖÂÍøÂçÉ豸CPU¸ºÔعý¸ßÎÞ·¨Õý³£¹¤×÷£¬DHCPÇëÇ󷺺鹥»÷£¬µ¼ÖÂDHCP·þÎñÆ÷µØÖ·¿Ý½ß£¬Óû§ÎÞ·¨Õý³£»ñÈ¡IPµØÖ··ÃÎÊÍøÂç¡£

    RG-S2910XS-EϵÁÐÌṩҵ½çÏȽøµÄÓ²¼þCPU±£»¤»úÖÆ£ºÌØÓеÄCPU±£»¤²ßÂÔ£¨CPP£¬CPU Protect Policy£©£¬¶Ô·¢ÍùCPUµÄÊý¾ÝÁ÷£¬½øÐÐÁ÷Çø·ÖºÍÓÅÏȼ¶¶ÓÁзּ¶´¦Àí£¬²¢¸ù¾ÝÐèҪʵʩ´ø¿íÏÞËÙ£¬³ä·Ö±£»¤CPU²»±»·Ç·¨Á÷Á¿Õ¼ÓᢶñÒâ¹¥»÷ºÍ×ÊÔ´ÏûºÄ£¬±£ÕÏÁËCPU°²È«£¬³ä·Ö±£»¤Á˽»»»»úµÄ°²È«¡£

    RG-S2910XS-EϵÁÐÌṩÏȽøµÄ»ù´¡ÍøÂç±£»¤²ßÂÔ£¨NFPP£¬Network Foundation Protection Policy£©¼¼Êõ£¬Äܹ»ÏÞÖÆÓû§ÏòÍøÂçÖз¢ËÍARP±¨ÎÄ¡¢ICMPÇëÇó±¨ÎÄ¡¢DHCPÇëÇó±¨ÎĵÈÊý¾Ý°üµÄËÙÂÊ£¬¶Ô³¬¹ýÏÞËÙãÐÖµµÄ±¨ÎĽøÐжªÆú´¦Àí£¬ÉõÖÁÄܹ»Ê¶±ð¹¥»÷ÐÐΪ£¬¶ÔÓй¥»÷ÐÐΪµÄÓû§½øÐиôÀë¡£´Ó¶ø±£»¤»ù´¡ÍøÂçÃâÊÜÍøÂç¹¥»÷ÐÐΪµÄÓ°Ï죬±£ÕÏÍøÂçÎȶ¨¡£

    Ö§³ÖDHCP snooping£¬¿ÉÖ»ÔÊÐíÐÅÈζ˿ڵÄDHCPÏìÓ¦£¬·Àֹ˽ÉèDHCP ServerµÄÆÛÆ­£»²¢ÔÚDHCP¼àÌýµÄ»ù´¡ÉÏ£¬Í¨¹ý¶¯Ì¬¼à²âARPºÍ¼ì²éÓû§µÄIP£¬Ö±½Ó¶ªÆú²»·ûºÏ°ó¶¨±íÏîµÄ·Ç·¨±¨ÎÄ£¬ÓÐЧ·À·¶ARPÆÛÆ­ºÍÓû§Ô´IPµØÖ·µÄÆÛÆ­ÎÊÌâ¡£

    ÐéÄâ½»»»µ¥Ôª£¨VSU£¬Virtual Switching Unit£©

    RG-S2910XS-EϵÁвúÆ·Ö§³ÖÐéÄâ½»»»µ¥Ôª£¨VSU£¬Virtual Switching Unit£©¡£Äܹ»½«¶ą̀ÎïÀíÉ豸½øÐл¥Áª£¬Ê¹ÆäÐéÄâΪһ̨Âß¼­É豸£¬ÀûÓõ¥Ò»IPµØÖ·¡¢µ¥Ò»Telnet½ø³Ì¡¢µ¥Ò»ÃüÁîÐнӿÚ(CLI)¡¢×Ô¶¯°æ±¾¼ì²é¡¢×Ô¶¯ÅäÖõÈÌØÐÔ½øÐйÜÀí£¬¶ÔÓû§À´Ëµ½ö½öÊÇÔÚ¹ÜÀíһ̨É豸£¬µ«ÊÇȴʵÏÖ×Ŷą̀É豸´øÀ´µÄ¹¤×÷ЧÂʺÍʹÓÃÌåÑé¡£

    ¼ò»¯¹ÜÀí£º¹ÜÀíÔ±¿ÉÒÔ¶Ô¶ą̀½»»»»úͳһ¹ÜÀí£¬¶ø²»ÐèÒªÁ¬½Óµ½Ã¿Ì¨½»»»»ú·Ö±ð½øÐÐÅäÖú͹ÜÀí¡£

    ¼ò»¯ÍøÂçÍØÆË£ºVSUÔÚÍøÂçÖÐÏ൱ÓÚһ̨½»»»»ú£¬Í¨¹ý¾ÛºÏÁ´Â·ºÍÍâΧÉ豸Á¬½Ó£¬²»´æÔÚ¶þ²ã»·Â·£¬Ã»±ØÒªÅäÖÃMSTPЭÒ飬¸÷ÖÖ¿ØÖÆÐ­ÒéÊÇ×÷Ϊһ̨½»»»»úÔËÐеÄ¡£

    ºÁÃë¼¶¹ÊÕϻָ´£ºVSUºÍÍâΧÉ豸ͨ¹ý¾ÛºÏÁ´Â·Á¬½Ó£¬Èç¹ûÆäÖÐһ̨É豸»òÕßÒ»Ìõ³ÉÔ±Á´Â·³öÏÖ¹ÊÕÏ£¬Çл»µ½ÁíÒ»Ìõ³ÉÔ±Á´Â·µÄʱ¼äÖ»ÐèÒª50µ½200ºÁÃë¡£

    ¸ßÀ©Õ¹ÐÔ£ºÓû§ÐÂÔöµÄÉ豸¼ÓÈë»òÀ뿪ÐéÄâ»¯ÍøÂçʱ¿ÉÒÔʵÏÖ“ÈȲå°Î”£¬²»Ó°ÏìÆäËûÉ豸µÄÕý³£ÔËÐС£

    ±£»¤Í¶×Ê£ºVSUºÍÍâΧÉ豸ͨ¹ý¾ÛºÏÁ´Â·Á¬½Ó£¬¼ÈÌṩÁËÈßÓàÁ´Â·£¬ÓÖ¿ÉÒÔʵÏÖ¸ºÔؾùºâ£¬³ä·ÖÀûÓÃËùÓÐÍøÂçÉ豸ºÍ´ø¿í×ÊÔ´¡£Í¬Ê±¿ÉÓÃÈÎÒâÐÎ̬µÄÍòÕ×¶Ë¿Úͨ¹ýÈÎÒâµÄÊý¾Ý´«ÊäÏßÀÂ×é³ÉVSUÐéÄâÍøÂçϵͳ£¬²»ÐèÒª¶îÍâÅäÖÃÏßÀ¡¢À©Õ¹¿¨£¬²¢ÇÒûÓж˿ںÍÏßÀÂÖÖÀàµÄÏÞÖÆ£¬±£»¤Óû§µÄͶ×Ê¡£

    ¸ß¿É¿¿ÐÔ

    Ö§³ÖÉú³ÉÊ÷ЭÒéSTP¡¢RSTP¡¢MSTP£¬±£Ö¤¿ìËÙÊÕÁ²£¬Ìá¸ßÈÝ´íÄÜÁ¦£¬±£Ö¤ÍøÂçµÄÎȶ¨ÔËÐкÍÁ´Â·µÄ¸ºÔؾùºâ£¬ºÏÀíʹÓÃÍøÂçͨµÀ£¬ÌṩÈßÓàÁ´Â·ÀûÓÃÂÊ¡£

    Ö§³ÖÐéÄâ·ÓÉÆ÷ÈßÓàЭÒ飨VRRP£©£¬ÓÐЧ±£ÕÏÍøÂçÎȶ¨¡£

    Ö§³Ö¿ìËÙÁ´Â·¼ì²âЭÒ飨RLDP£¬Rapid Link Detection Protocol£©£¬¿É¿ìËÙ¼ì²âÁ´Â·µÄͨ¶ÏºÍ¹âÏËÁ´Â·µÄµ¥ÏòÐÔ£¬²¢Ö§³Ö¶Ë¿ÚÏµĻ·Â·¼ì²â¹¦ÄÜ£¬·ÀÖ¹¶Ë¿ÚÏÂÒò˽½ÓHubµÈÉ豸ÐγɵĻ·Â·¶øµ¼ÖÂÍøÂç¹ÊÕϵÄÏÖÏó¡£

    Ö§³Ö¹«ÓÐÒÔÌ«Íø¶à»·±£»¤¼¼Êõ£¨ERPS£©£¬¹ú¼Ê±ê׼ΪºËÐÄÒÔÌ«ÍøÉè¼ÆµÄ¶þ²ãÁ´Â·ÈßÓ౸·ÝЭÒ飬Æä»·Â·×è¶ÏÒÔ¼°Á´Â·»Ö¸´¶¼¼¯ÖÐÔÚÖ÷¿ØÉ豸ÉϽøÐУ¬·ÇÖ÷¿ØÉ豸ֱ½ÓÏòÖ÷¿ØÉ豸»ã±¨×Ô¼ºµÄÁ´Â·Çé¿ö£¬ÎÞÐè¾­¹ýÆäËû·ÇÖ÷¿ØÉ豸µÄ´¦Àí£¬Òò´Ë»·Â·ÖжÏÒÔ¼°»Ö¸´Ê±¼ä±ÈSTP¿ì¡£»ùÓÚÒÔÉÏÇø±ð£¬ERPSÔÚÀíÏë»·¾³ÏµÄÁ´Â·»Ö¸´ÄÜÁ¦Äܹ»´ïµ½ºÁÃë¼¶¡£

    ÔÚ²»ÆôÓÃSTPµÄÇé¿öÏ£¬¿ÉÒÔͨ¹ý¿ìËÙÁ´Â·¼ì²âЭÒ飨RLDP£¬Rapid Link Detection Protocol£©Ìṩһ¸ö¿ìËÙÉÏÁ´±£»¤¹¦ÄÜ£¬REUPʹµÃÓû§ÔڹرÕSTPµÄÇé¿öÏ£¬ÈÔÌṩ»ù±¾µÄÁ´Â·ÈßÓ࣬ͬʱÌṩ±ÈSTP¸ü¿ìµÄºÁÃë¼¶¹ÊÕϻָ´¡£

    Èí¼þ¶¨ÒåÍøÂ磨SDN£©

    RG-S2910XS-EϵÁвúÆ·¸úËæÊ±´ú·¢Õ¹£¬Ö§³ÖOpenFlow 1.3£¬¿ÉÒԺ͹«º£²Ê´¬¡¤6600ÍøÂç×ÔÑÐSDN controller Ï໥ÅäºÏ£¬ÇáËÉʵÏÖ´ó¹æÄ£¶þ²ã¼Ü¹¹×éÍø£¬²¢ÇÒÖ§³ÖÕûÍøÆ½»¬Éý¼¶µ½SDNÍøÂ磬ÔÚ´ó·ù¼ò»¯ÍøÂç¹ÜÀíµÄÄѶȵÄͬʱ¿ÉÏÔÖø½µµÍÍøÂçά»¤µÄ³É±¾¡£

    ÂÌÉ«½ÚÄÜ

    RG-S2910XS-EϵÁн»»»»ú³ä·ÖÏàÓ¦¹ú¼ÒÂÌÉ«½ÚÄܵĺÅÕÙ£¬²ÉÓöàÖÖÂÌÉ«½ÚÄܵÄÉè¼ÆÀíÄÕë¶Ô´«Í³½»»»»úÔÚÔëÒô¼°Äܺķ½Ãæ´æÔÚµÄÎÊÌâ½øÐÐÉîÈëÑо¿Ì½Ë÷£¬³ä·Ö½â¾öÁ˽»»»»ú²¿ÊðÔڰ칫»·¾³ÔëÉù´ó¡¢ÒÔ¼°½ÓÈëÉ豸´óÅúÁ¿²¿Êðºó´øÀ´µÄÄܺĹý´óµÄÎÊÌâ¡£

    RG-S2910XS-EϵÁн»»»»ú²ÉÓÃÁËÐÂÒ»´úµÄÓ²¼þ¼Ü¹¹ÒÔ¼°ÏȽøµÄ½ÚÄܵç·Éè¼ÆºÍÔªÆ÷¼þÑ¡ÐÍ¡£É豸µÄÕûÌ幦ºÄ½µµÍÁË40%ÒÔÉÏ£¬¸ü´ó³Ì¶ÈΪÓû§½ÚÊ¡ÄܺÄ£¬Í¬Ê±½µµÍÔëÒôÎÛȾ¡£È«ÏµÁвúÆ·¾ù²ÉÓÃÖáÁ÷±äËÙ·çÉÈÉè¼Æ£¬É豸¿É¸ù¾Ýµ±Ç°µÄζÈÖÇÄÜ¿ØÖÆ·çÉÈתËÙ£¬±£ÕÏÉ豸Îȶ¨¹¤×÷µÄͬʱ£¬½µµÍ¹¦ºÄºÍÔëÉù¡£ÆäÖÐV2.00¼°ÒÔÉÏÓ²¼þ°æ±¾µÄ²úÆ·(·ÇPoEÐͺÅ)£¬²ÉÓþ²ÒôÉè¼Æ£¬³£ÎÂϹ¤×÷ÔëÉù≤35db¡£

    ÔÚPoE¹©µç×éÍø»·¾³ÖУ¬RG-S2910XS-EϵÁвúÆ·¸ù¾Ý²»Í¬Óû§µÄʵ¼ÊÐèÒª£¬PoE¹©µçÌṩ×Ô¶¯Ä£Ê½¡¢½ÚÄÜģʽ¡¢¾²Ì¬Ä£Ê½ÈýÖÖģʽÈÃÓû§Ñ¡Ôñ¡£

    RG-S2910XS-EϵÁн»»»»úÖ§³Ö¸ßЧ½ÚÄÜÒÔÌ«Íø£¨EEE£©£¬¶Ë¿ÚÈç¹ûÔÚÁ¬ÐøÒ»¶Îʱ¼äÖ®ÄÚ¿ÕÏУ¬ÏµÍ³»á½«¸Ã¶Ë¿ÚÉèÖÃΪ½ÚÄÜģʽ£¬µ±Óб¨ÎÄÊÕ·¢Ê±ÔÙͨ¹ý¶¨Ê±·¢Ë͵ļàÌýÂëÁ÷»½ÐѶ˿ڻָ´ÒµÎñ£¬´ïµ½½ÚÄܵÄЧ¹û¡£

    RG-S2910XS-EϵÁвúƷͬʱÂú×ã²ÄÁÏ»·±£Ó밲ȫÐÔµÄÅ·ÃËRoHS±ê×¼£¬·ûºÏSJ/T 11363/11364/11365µÈ¹ú¼ÒÈÏÖ¤ÒªÇó¡£

    ¼òµ¥ÇáËɵÄÍøÂçά»¤

    RG-S2910XS-EϵÁÐÖ§³ÖSNMP¡¢RMON¡¢Syslog¡¢sFLOW¡¢USB±¸·ÝÈÕÖ¾¼°ÅäÖõÈÌØÐÔÀ´½øÐÐÍøÂçµÄÈÕ³£Õï¶Ï¼°Î¬»¤£¬Í¬Ê±¹ÜÀíÔ±¿É²ÉÓÃCLI¡¢WebÍø¹Ü¡¢Telnet¡¢CWMP(TR069)µÈ¶àÑù»¯µÄ¹ÜÀíºÍά»¤·½Ê½¸ü·½±ãÉ豸µÄ¹ÜÀí¡£

    Ö§³Ö»ùÓÚSNMP¡¢ERSPAN¡¢NetconfµÈ¼¼ÊõµÄTelemetry£¬ÊµÏÖ¶Ô½»»»»úÔËÐÐ״̬ÐÅÏ¢µÄ²É¼¯¡£

    PoEʹÓÃ״̬һĿÁËÈ»£ºÃæ°å×Ô´øÒ»¼ü²é¿´PoE¹©µç״̬¹¦ÄܵÄPoE°´Å¥£¬Çá°´¼´¿É²é¿´É豸µ±Ç°µÄͨÐÅ״̬ºÍ¹©µç״̬£¬ÈÃÄú¶ÔËùÓж˿ÚPoE¹©µçµÄ״̬ÁËÈ»ÓÚÐÄ¡£

    ¼¼Êõ²ÎÊý

    Ó²¼þ¹æ¸ñ

    Ó²¼þ¹æ¸ñ

    RG-S2910-24GT4XS-E

    RG-S2910-48GT4XS-E

    ϵͳ¹æ¸ñ

    °üת·¢ÂÊ

    171Mpps

    207Mpps

    ½»»»ÈÝÁ¿

    672Gbps/6.72Tbps

    672Gbps/6.72Tbps

    ½Ó¿Ú¹æ¸ñ

    ¹Ì»¯ÒµÎñ½Ó¿Ú

    24¿Ú10/100/1000M×ÔÊÊÓ¦µç¿Ú£¬

    4¸ö1G/10G SFP+¹â¿Ú£¬

    48¿Ú10/100/1000M×ÔÊÊÓ¦µç¿Ú£¬4¸ö1G/10G SFP+¹â¿Ú£¬

    Ä£¿é²å²Û

    0¸öÀ©Õ¹²Û

    0¸öÀ©Õ¹²Û

    À©Õ¹Ä£¿é

    ÎÞ

    ÎÞ

    µçÔ´Ó빦ºÄ

    ¹Ì»¯µçÔ´ÊýÁ¿

    ¹Ì»¯µ¥½»Á÷µçÔ´

    ¶î¶¨ÊäÈëµçѹ

    ½»Á÷£¨AC£©ÊäÈ룺

    ¡ñ ¶î¶¨µçѹ·¶Î§£º100V~240V

    ¡ñ ƵÂÊ£º50/60Hz

    ×î´óÊäÈëµçѹ

    ½»Á÷£¨AC£©ÊäÈ룺

    ¡ñ ×î´óµçѹ·¶Î§£º90V~264V

    ¡ñ ƵÂÊ£º50/60Hz

    ÊäÈëµçѹ

    ¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺

    ÊäÈëµçѹ·¶Î§£º192V~290V

    µäÐ͹¦ºÄ

    ≤24W

    £¨¾²Ì¬≤15.1W£©

    ≤50W

    £¨¾²Ì¬≤32.5W£©

    POE¹©µç±ê×¼

    ²»Ö§³Ö

    PoE¹¦ÄÜ

    ²»Ö§³Ö

    ³ß´çÓëÖØÁ¿

    ²úÆ·³ß´ç£¨¿í×Éî׸ߣ©

    V1.XX°æ±¾£º

    443.0mm x 268.0mm x 44.5mm

    V2.XX¼°ÒÔÉϰ汾£º

    440mm x 220mm x 44mm

    »·¾³Óë¿É¿¿ÐÔ

    ¹¤×÷ζÈ

    0¡æ~50¡æ

    ´æ´¢Î¶È

    -40¡æ~70¡æ

    ·çÉÈ¼à¿Ø

    Ö§³Ö·çÉȵ÷ËÙ¼°·çÉȹÊÕϸ澯¹¦ÄÜ

    ¹¤×÷ʪ¶È

    10%~90%RH

    ´æ´¢Êª¶È

    5%~95%RH

    ͨÐŽӿڷÀÀ×

    ¹²Ä£10kV£¬²îÄ£500V(V2.XX¼°ÒÔÉÏÓ²¼þ°æ±¾)

    µçÔ´½Ó¿Ú·ÀÀ×

    ¹²Ä£6kV£¬²îÄ£6kV

     

    Èí¼þ¹æ¸ñ

    ¶þ²ãÌØÐÔ

    RG-S2910-24GT4XS-E

    RG-S2910-48GT4XS-E

    802.1Q VLAN

    Ö§³Ö4K 802.1Q VLAN

    Ö§³ÖPort based VLAN

    Ö§³ÖMAC based VLAN

    Ö§³ÖProtocol based VLAN

    Ö§³ÖPrivate VLAN

    Ö§³ÖVoice VLAN

    Ö§³ÖIP subnet-based VLAN

    Ö§³ÖGVRP

    QinQ

    Ö§³Ö»ù±¾QinQ

    Ö§³ÖÁé»îQinQ

    ACL

    Ö§³Ö±ê×¼IP ACL£¨»ùÓÚIPµØÖ·µÄÓ²¼þACL£©

    Ö§³ÖÀ©Õ¹IP ACL£¨»ùÓÚIPµØÖ·¡¢TCP/UDP¶Ë¿ÚºÅµÄÓ²¼þACL£©

    Ö§³ÖMACÀ©Õ¹ACL£¨»ùÓÚÔ´MACµØÖ·¡¢Ä¿µÄMACµØÖ·ºÍ¿ÉÑ¡µÄÒÔÌ«ÍøÀàÐ͵ÄÓ²¼þACL£©

    Ö§³Ö»ùÓÚʱ¼äACL

    Ö§³Öר¼Ò¼¶ACL £¨¿Éͬʱ»ùÓÚVLANºÅ¡¢ÒÔÌ«ÍøÀàÐÍ¡¢MACµØÖ·¡¢IPµØÖ·¡¢TCP/UDP¶Ë¿ÚºÅ¡¢Ð­ÒéÀàÐÍ¡¢Ê±¼äµÈÁé»î×éºÏµÄÓ²¼þACL£©

    Ö§³ÖACL80

    Ö§³ÖIPv6 ACL

    Ö§³ÖÈ«¾ÖACL

    Ö§³ÖACLÖØ¶¨Ïò

    QoS

    Ö§³Ö¶Ë¿ÚÁ÷Á¿Ê¶±ð

    Ö§³Ö¶Ë¿ÚÁ÷Á¿ÏÞËÙ

    Ö§³Ö802.1p/DSCP/TOSÁ÷Á¿·ÖÀà

    ÿ¶Ë¿Ú8¸öÓÅÏȼ¶¶ÓÁÐ

    Ö§³ÖSP¡¢WRR¡¢DRR¡¢SP+WFQ¡¢ SP+WRR¡¢SP+DRR¡¢RED/WRED¶ÓÁе÷¶È

    Mirror

    Ö§³ÖÒ»¶ÔÒ»¡¢¶à¶ÔÒ»¡¢Ò»¶Ô¶àµÄ¾µÏñ

    Ö§³ÖRSPAN¡¢ERSPAN

    Ö§³Ö»ùÓÚÁ÷µÄ±¾µØ¡¢Ô¶³Ì¾µÏñ

    DHCP

    Ö§³ÖDHCP Server

    Ö§³ÖDHCP Client

    Ö§³ÖDHCP Snooping

    Ö§³ÖDHCP Relay

    Ö§³ÖIPv6 DHCP Snooping

    Ö§³ÖIPv6 DHCP Client

    Ö§³ÖIPv6 DHCP Relay

    °²È«ÌØÐÔ

    Ö§³ÖIP¡¢MAC¡¢¶Ë¿ÚÈýÔªËØ°ó¶¨

    Ö§³ÖIPv6¡¢MAC¡¢¶Ë¿ÚÈýÔªËØ°ó¶¨

    ¹ýÂË·Ç·¨µÄMACµØÖ·

    Ö§³Ö»ùÓڶ˿ںÍMACµÄ802.1x

    Ö§³ÖMAB

    Ö§³ÖPortal ºÍPortal 2.0ÈÏÖ¤

    Ö§³ÖARP-Check

    Ö§³ÖDAI

    Ö§³ÖARP±¨ÎÄÏÞËÙ

    Ö§³Ö·ÀÍø¹ØARPÆÛÆ­

    Ö§³Ö¹ã²¥·ç±©ÒÖÖÆ

    ¹ÜÀíÔ±·Ö¼¶¹ÜÀíºÍ¿ÚÁî±£»¤

    Ö§³ÖRADIUS ºÍ TACACS+

    É豸µÇ½¹ÜÀíµÄAAA°²È«ÈÏÖ¤£¨IPv4/IPv6£©

    Ö§³ÖSSH ºÍ SSH V2.0

    Ö§³ÖBPDU Guard

    Ö§³ÖIP SOURCE Guard

    Ö§³ÖCPP¡¢NFPP

    Ö§³Ö¶Ë¿Ú±£»¤

    ÏßÀ¼ì²â

    Ö§³ÖÏßÀ¼ì²â

    EEE

    Ö§³ÖIEEE 802.3az±ê×¼µÄ EEE½ÚÄܼ¼Êõ£ºµ±EEEʹÄÜʱ£¬´Ó¶ø´ó·ù¶ÈµÄ¼õС¶Ë¿ÚÔڸý׶εŦºÄ£¬´ïµ½Á˽ÚÄܵÄÄ¿µÄ¡£

    »·ÍøÐ­Òé

    Ö§³ÖG.8032¹ú¼Ê±ê×¼»·ÍøÐ­ÒéERPS£¬Çл»Ê±¼ä≤50ms£¬¿ÉÓëÆäËûÖ§³Ö¸ÃЭÒéµÄ²úÆ·ÍêÃÀ¼æÈÝ

    ¶Ë¿ÚÐÝÃß

    Ö§³Ö¶Ë¿ÚÐÝÃß

     


    Èý²ãÌØÐÔ

    RG-S2910-24GT4XS-E

    RG-S2910-48GT4XS-E

    IP·ÓÉ

    IPv4/IPv6 ¾²Ì¬Â·ÓÉ

    RIP¡¢RIPng¡¢OSPFv2¡¢OSPFv3

    Routing Policy

    IPv6

    »ù´¡Ð­Òé

    IPv6±àÖ·¡¢ÁÚ¾Ó·¢ÏÖЭÒ飨ND£©¡¢ICMPv6¡¢IPv6 Ping¡¢IPv6 TracertµÈ

    VSUÌØÐÔ

    Ö§³ÖVSUÐéÄ⻯¼¼Êõ

    Ö§³Ö±¾µØ¶ÑµþºÍÔ¶³Ì¶Ñµþ

    Ö§³Ö¶ÑµþÄÚ¿ç»úÏäµÄÁ´Â·À¦°ó

    Ö§³Öͨ¹ý±ê×¼ÒµÎñ¿ÚʵÏÖÐéÄ⻯£¨·Ç¶Ñµþ²å¿¨£¬²»Õ¼ÓÃÀ©Õ¹²Û룩

    ¼«¼òÍøÂç

    Ö§³ÖÓëºËÐÄÉ豸¹¹½¨´ó¶þ²ãÍøÂ磬ͨ¹ýVSUµÈÐéÄ⻯¼¼ÊõʵÏÖÍøÂç×ÊÔ´³Ø»¯£¬Ö»ÐèÒª¹ÜÀíºËÐÄÉ豸£¬´Ó¶ø¼ò»¯ºáÏòºÍ×ÝÏòÍøÂçµÄ¹ÜÀíºÍά»¤

    ÁãÅäÖÃ

    Ö§³ÖCWMP(TR069)ЭÒé±ê׼ЭÒé

    ¹ÜÀíÌØÐÔ

    SNMPv1/v2c/v3¡¢CLI(Telnet/Console)¡¢RMON(1£¬2£¬3£¬9)¡¢SSH¡¢Syslog¡¢NTP/SNTP¡¢FTP¡¢TFTP¡¢Web¡¢sFLOW

     

    Õ¹¿ªÏêϸ²ÎÊý

    ×ÊÔ´ÖÐÐÄ

    ÓªÏú×ÊÁÏ
    Ó¦Óð¸Àý
    ¼¼Êõ²©ÎÄ
    ÊÛºóÎĵµ

    ³£¼ûÎÊÌâ

    ÎÒÒªÌáÎÊ
    È«²¿
    µçÔ´(1)
    Èý²ã½»»»»ú(2)
    »·Íø½»»»»ú(1)
    »·Â·¼ì²â(1)
    ½»»»Íø°å(1)
    ¹«º£²Ê´¬¡¤6600 2022Äê07ÔÂ25ÈÕ
    ¸Ã¿î½»»»»úÊǼ¸²ã½»»»»ú£¿
    ÓÐÓÃ 138 ÎÞÓÃ 19

    Èý²ãµÄ£¬RG-S2910XS-E¡¢RG-S2910-H¡¢RG-S2910G-P¡¢RG-S2910V2¡¢RG-S2910-LµÈϵÁн»»»»ú¶¼ÊÇÈý²ã½»»»»ú¡£

    ¹«º£²Ê´¬¡¤6600 2022Äê07ÔÂ25ÈÕ
    ÐèÒª»·Íø½»»»»ú£¬ÓÐÍÆ¼öµÄÐͺÅÂð£¿
    ÓÐÓÃ 70 ÎÞÓÃ 3

    ÎÒ˾֧³Ö“ERPSЭÒ锵Ľ»»»»ú¶¼ÊÇ»·Íø½»»»»ú£¬ÈçRG- S2900G-E V3 ºÍ RG-S2910XS-EϵÁÐǧÕ×½»»»»ú¡£

    Õ¹¿ªÈ«²¿
    Èç¹ûÄúÐèÒª¸ü¶à²úÆ·¼¼Êõ×Éѯ
    ¾ßÌåÐÔÄÜÄÜ·ñÂú×ãÄúµÄÒµÎñ·åÖµ£¿ÈçºÎ¹æ»®²¿ÊðÓëÅäÖã¿
    Á¢¼´×Éѯ

    ·µ»Ø¶¥²¿

    ÊÕÆð
    ÎĵµAIÖúÊÖ
    ÎĵµÆÀ¼Û
    ¸Ã×ÊÁÏÊÇ·ñ½â¾öÁËÄúµÄÎÊÌ⣿
    Äú¶Ôµ±Ç°Ò³ÃæµÄÂúÒâ¶ÈÈçºÎ£¿
    ²»Õ¦µÎ
    ·Ç³£ºÃ
    ÄúÂúÒâµÄÔ­ÒòÊÇ£¨¶àÑ¡£©£¿
    Äú¶ÔÎĵµÊÇ·ñ»¹ÓÐÆäËüµÄÎÊÌâ»ò½¨Ò飿
    Ϊ¾¡¿ì½â¾öÎÊÌ⣬ÇëÄúÁôÏÂÁªÏµ·½Ê½Òﱋȯ¸´
    ÓÊÏä
    ÊÖ»úºÅ
    ¸ÐлÄúµÄ·´À¡£¡
    ÇëÑ¡Ôñ·þÎñÏîÄ¿
    ¹Ø±Õ×Éѯҳ
    ÊÛǰ×Éѯ ÊÛǰ×Éѯ
    ÊÛǰ×Éѯ
    ÊÛºó·þÎñ ÊÛºó·þÎñ
    ÊÛºó·þÎñ
    Òâ¼û·´À¡ Òâ¼û·´À¡
    Òâ¼û·´À¡
    ¸ü¶àÁªÏµ·½Ê½
    ¡¾ÍøÕ¾µØÍ¼¡¿¡¾sitemap¡¿