¹«º£²Ê´¬¡¤6600(ÖйúÓÎ)¹Ù·½ÍøÕ¾


  • µã»÷ÏÂÔØ¡¶ÍòÕ×Ô°ÇøÒÔÌ«²Ê¹âÑо¿±¨¸æ¡·£¬½âËøÍòÕ×Ô°ÇøÍøÂ罨ÉèÖ¸ÄÏ
    Á¢¼´ÏÂÔØ
    ÎÞ¸Ð×¼Èë ÈËÎïͳ¹Ü Ø­ RG-SAM+5.X ÐÂÒ»´ú¸ßУAIÈÏ֤ƽ̨·¢²¼
    Ô¤Ô¼Ö±²¥
    ²úÆ·
    < ·µ»ØÖ÷²Ëµ¥
    ²úÆ·ÖÐÐÄ
    ²úÆ·
    ºÏ×÷»ï°é
    ·µ»ØÖ÷²Ëµ¥
    Ñ¡ÔñÇøÓò/ÓïÑÔ
    RG-S7807E
    RG-S7807E
    RG-S7807E
    ¼ÓÔØÖÐ...0%
    ͼƬ

    RG-S7807E

    RG-S7807E

    ÀàÐÍ£º

    ²úÆ·ÌØÐÔ£º

    Á¢¼´×Éѯ

    ÔÆ¼Ü¹¹ÍøÂçºËÐÄ£¬¸ß¼¶ÅäÖÃ

    ¸ßÐÔÄÜÂú×ãδÀ´Ê®ÄêÍøÂç·¢Õ¹

    RG-S7800EϵÁÐÖ§³ÖÒµ½ç¸ßÐÔÄܵÄС°üÏßËÙת·¢ÄÜÁ¦£¬°üÀ¨¸ßÃܶȰ忨ÔÚÄÚµÄËùÓа忨¾ù¿ÉʵÏÖ64×Ö½ÚС°üÏßËÙת·¢£¬´ÓÈÝÓ¦¶ÔδÀ´ÍøÂç¶Ô¸ßËÙת·¢²»¶ª°üµÄ¿Á¿ÌÐèÇó¡£

    ÐéÄ⻯ÈÃ×ÊÔ´°´Ðè·ÖÅä

    ÐéÄâ½»»»µ¥ÔªVSU3.0

    RG- S7800EϵÁÐÖ§³ÖÒµ½ç³¬Ç°µÄVSU3.0£¨Virtual Switching Unit£¬ÐéÄâ½»»»µ¥Ôª£©ÐéÄ⻯¼¼Êõ£¬½«¶ą̀ÎïÀíÉ豸ÐéÄ⻯Ϊһ̨Âß¼­É豸£¬Í³Ò»ÔËÐйÜÀí£¬´ó·ù¼õÉÙÍøÂç½Úµã£¬½µµÍÍøÂçÔËά¹ÜÀíÈËÔ±¹¤×÷Á¿¡£Ôö¼ÓÍøÂç¿É¿¿ ÐÔ£¬ÊµÏÖ50~200msÁ´Â·¹ÊÕÏ¿ìËÙÇл»£¬±£ÕϹؼüÒµÎñ²»Öжϴ«Êä¡£Ö§³Ö¿çÉ豸Á´Â·¾ÛºÏ£¬·½±ã½ÓÈë·þÎñÆ÷/½»»»»úʵÏÖË«»îÁ´Â·ÉÏÁª£¬ÍøÂçÓÐЧÁ¬½Ó´ø¿í³É ±¾Ôö³¤¡£

    ÐéÄâ½»»»É豸VSD

    RG- S7800EϵÁÐͨ¹ýVSD£¨Virtual Switch Device£¬ÐéÄâ½»»»É豸£©¼¼Êõ¿É½«Ò»Ì¨É豸ÐéÄ⻯Ϊ¶ą̀ÐéÄâÉ豸£¬Ã¿Ì¨ÐéÄâÉ豸¾ßÓжÀÁ¢µÄÅäÖùÜÀí½çÃæ¡¢¶ÀÁ¢Ó²¼þ×ÊÔ´·ÖÅä(±ÈÈçÄÚ´æ¡¢TCAM¡¢Ó²¼þ ת·¢±í)£¬¿ÉÒÔ¶ÀÁ¢ÖØÆô¶ø²»Ó°ÏìÆäËüµÄÐéÄâ½»»»»ú¡£ÓÐЧΪÄúʵÏÖÍøÂç×ÊÔ´µÄ°´Ðè·ÖÅ䣬¿ÉÈúËÐĽ»»»»ú×ÊԴͬʱ¹²Ïí¸ø¶à¸öÇøÓò»òÓû§Ê¹Óá£

    µçÐż¶µÄ¸ß¿É¿¿ÐÔÉè¼Æ

    RG-S7800EϵÁи÷¹Ø¼ü²¿¼þ¾ùΪÈßÓàÉè¼Æ£ºÖ÷¿ØÒýÇæ1+1ÈßÓ࣬·çÉÈN+MÈßÓ࣬µçÔ´Ä£¿éN+MÈßÓ࣬ͬʱ¸÷ÈßÓà×é¼þ¾ùÖ§³ÖÈȲå°Î£¬ÓÐЧÌá¸ßÕû»úµÄ¿É¿¿ÐԺͿÉÓÃÐÔ¡£

    Ö§³ÖÈȲ¹¶¡ºÍISSU¼¼Êõ£¬¿ÉʵÏÖÉ豸ÔÚÏß½øÐв¹¶¡Éý¼¶¡£

    Ö§³ÖGR for OSPF/IS-IS/BGPµÈ£¬Ö§³ÖBFD for VRRP/OSPF/BGP4/ISIS/ISISv6/MPLS/¾²Ì¬Â·ÓɵÈ£¬ÊµÏÖ¸÷ЭÒéµÄ¿ìËÙ¹ÊÕϼì²â»úÖÆ£¬¹ÊÕϼì²âʱ¼äСÓÚ50ms¡£

    ¶à½ø³ÌÄ£¿é»¯²Ù×÷ϵͳ

    ´Ó 1998ÄêÆð£¬¹«º£²Ê´¬¡¤6600ÍøÂç¾Í¿ªÊ¼ÁËÄ£¿é»¯²Ù×÷ϵͳµÄÑз¢Í¶È룬RG-S7800EϵÁÐÈí¼þƽ̨»ùÓÚÐÂÒ»´úµÄRGOS 11.X¶à½ø³ÌÄ£¿é»¯²Ù×÷ϵͳ£¬½«ËÉñîºÏµÄ·À»ðǽ¡¢ÎÞÏß¡¢IPFIX¡¢ÈÏÖ¤µÈÒµÎñÌØÐԹ鲢µ½Í³Ò»ÔƼܹ¹ÍøÂç²Ù×÷ϵͳƽ̨£¬Ö§³ÖÐéÄ⻯ÄÜÁ¦ºÍ·á¸»µÄÊý ¾ÝÖÐÐĺÍÔ°ÇøÍøÌØÐÔ¡£ÔÚ¶à½ø³ÌÄ£¿é»¯¡¢½ø³Ì±¸·Ý¡¢ÈȲ¹¶¡µÈ¹Ø¼ü¿ÉÓÃÐÔÖ¸±êÉÏ´ïµ½Òµ½çµ±ÏÈˮƽ¡£

    ¸ßЧµÄÂÌÉ«½ÚÄÜ

    RG-S7800EϵÁвÉÓÃ40nmоƬ¹¤ÒÕ£¬Ïà±È´«Í³90nmºÍ65nm¹¤ÒÕ¸ü½ÚÄÜ¡£

    ÄÚ²¿ÏµÍ³µÍѹ¹©µçÉè¼Æ£¬¸ßЧÂÊÄ£¿é»¯µçÔ´£¬¹©µçϵͳЧÂʸü¸ß¡£

    ¶àºËCPUÖ§³Ö¶¯Ì¬¹¦ºÄ¹ÜÀí£¬È«²¿¹â¿Ú²ÉÓÃÎÞPHYÉè¼Æ£¬½µµÍ¹â¿Ú¹¦ºÄ£¬È«²¿ÒÔÌ«Íøµç¿ÚÖ§³ÖEEE¸ßЧ½ÚÄܱê×¼£¬µÍ¸ºÔØÊ±¿É½ÚÔ¼¹¦ºÄ¡£

    ÖÇÄÜ·çÉÈÖ§³Ö256¼¶µ÷ËÙ£¬¾«ÃÜοØ£¬½ÚÄܽµÔ룻¸ßÎÂÏ¿ɳ¤ÆÚ¹¤×÷£¬ÊÊÓ¦¶ñÁÓ»·¾³£¬ÎªÄú´ó·ù¶È½µµÍÄܺÄ¡£

    ¼¼Êõ²ÎÊý

    ¼¼Êõ²ÎÊý

    ²ÎÊýÃèÊö

    ²úÆ·ÐͺÅ

    RG-S7805E

    RG-S7807E

    RG-S7810E

    Ä£¿é²å²Û

    5¸ö£¨2¸öÓÃÓÚ¹ÜÀíÒýÇæÄ£¿é£©

    7¸ö£¨2¸öÓÃÓÚ¹ÜÀíÒýÇæÄ£¿é£©

    10¸ö£¨2¸öÓÃÓÚ¹ÜÀíÒýÇæÄ£¿é£©

    ½»»»ÈÝÁ¿

    4.8Tbps/12Tbps

    8Tbps/20Tbps

    12.8Tbps/32Tbps

    °üת·¢ËÙÂÊ

    1,440Mpps/5,400Mpps

    2,400Mpps/9,000Mpps

    3,840Mpps/14,400Mpps

    É豸ÐéÄ⻯

    Ö§³ÖVSU3.0(Virtual Switching Unit,ÐéÄâ½»»»µ¥Ôª)

    Ö§³ÖVSD(Virtual Switch Device,ÐéÄâ½»»»É豸)

    SDN

    Ö§³ÖOpenFlow 1.3

    L2 ÌØÐÔ

    Ö§³ÖJumbo Frame

    Ö§³Ö802.1Q

    Ö§³ÖSTP¡¢RSTP¡¢MSTP

    Ö§³ÖSuper VLAN

    Ö§³ÖGVRP

    Ö§³ÖQinQ¡¢Áé»îQinQ¡¢QinQÖÕ½á

    Ö§³ÖLLDP

    IPv4 ÌØÐÔ

    Ö§³Ö¾²Ì¬Â·ÓÉ¡¢RIP¡¢OSPF¡¢IS-IS¡¢BGP4

    Ö§³ÖVRRP

    Ö§³ÖµÈ¼Û·ÓÉ

    Ö§³Ö²ßÂÔ·ÓÉ

    Ö§³ÖGREËíµÀ

    IPv6 ÌØÐÔ

    Ö§³Ö¾²Ì¬Â·ÓÉ¡¢RIPng¡¢OSPFv3¡¢BGP4+¡¢IS-ISv6¡¢MLDv1/v2

    Ö§³ÖVRRPv3

    Ö§³ÖµÈ¼Û·ÓÉ

    Ö§³Ö²ßÂÔ·ÓÉ

    Ö§³ÖÊÖ¹¤ËíµÀ¡¢×Ô¶¯ËíµÀ¡¢ISATAPËíµÀ¡¢Ö§³ÖGREËíµÀµÈ

    ×é²¥

    Ö§³ÖIGMP v1,v2,v3

    Ö§³ÖIGMP Snooping

    Ö§³ÖIGMP Proxy

    Ö§³ÖPIM-DM¡¢PIM-SM¡¢PIM-SSMµÈ×鲥·ÓÉЭÒé

    Ö§³ÖMLD

    Ö§³Ö×é²¥¾²Ì¬Â·ÓÉ

    MPLS

    Ö§³ÖMPLSת·¢

    Ö§³ÖMPLS VPN/VPLS

    Ö§³ÖVPWS

    ACL

    Ö§³Ö±ê×¼¡¢À©Õ¹¡¢×¨¼Ò¼¶ACL

    Ö§³ÖACL 80

    Ö§³ÖIPv6 ACL

    QoS

    Ö§³Ö802.1P

    Ö§³ÖSP¡¢WRR¡¢DRR¡¢SP+WRR¡¢SP+DRRµÈ¶ÓÁе÷¶È»úÖÆ

    Ö§³ÖRED/WRED

    Ö§³Ö»ùÓÚ³ö¶Ë¿Ú/Èë¶Ë¿ÚµÄÏÞËÙ

    Ö§³ÖHQoS

    PoE

    Ö§³ÖÅäÖÃPoEÏß¿¨£¬²¢ÓɶÀÁ¢PoEµçÔ´²Û¹©µç£¬·ÀÖ¹ÒòPoE¹©µç¶øÓ°ÏìÆäËûÒµÎñÄ£¿é¹©µçÎȶ¨ÐÔ

    ¿É¿¿ÐÔ

    ¶ÀÁ¢µÄ½»»»Íø°åÓë¶ÀÁ¢µÄÖ÷¿Ø°åÉè¼Æ£¬ÊµÏÖת·¢Óë¿ØÖÆÆ½ÃæÍêÈ«·ÖÀë

    Ö÷¿Ø°åÖ§³Ö1+1ÈßÓ౸·Ý

    µçÔ´¡¢·çÉÈÖ§³ÖN+MÈßÓ౸·Ý

    ±³°åÎÞÔ´Éè¼Æ£¬±ÜÃâµ¥µã¹ÊÕÏ

    ¸÷×é¼þÖ§³ÖÈȲå°Î

    Ö§³ÖÈȲ¹¶¡¹¦ÄÜ£¬¿ÉÔÚÏß½øÐв¹¶¡Éý¼¶

    Ö§³ÖISSU

    Ö§³ÖGR for OSPF/IS-IS/BGP

    Ö§³ÖBFD for VRRP/OSPF/BGP4/ISIS/ISISv6/MPLS/¾²Ì¬Â·ÓɵÈ

    °²È«ÐÔ

    Ö§³ÖNFPP£¨»ù´¡°²È«±£»¤²ßÂÔ£©

    Ö§³ÖCPP£¨CPU±£»¤£©

    Ö§³ÖDAI£¬¶Ë¿Ú°²È«£¬IP Source Guard

    Ö§³Ö802.1x/Portal/MacµÈ¶àÖÖÈÏÖ¤·½Ê½

    Ö§³ÖRADIUSºÍTACACS+Óû§µÇ¼ÈÏÖ¤

    Ö§³ÖuRPF

    Ö§³ÖµÇ¼ÈÏÖ¤¡¢¿ÚÁȫ

    Ö§³Öδ֪×é²¥²»ËÍCPU¡¢Ö§³Öδ֪µ¥²¥ÒÖÖÆ

    Ö§³ÖSSHv2£¬ÎªÓû§µÇ¼Ìṩ°²È«¼ÓÃÜͨµÀ

    ¹ÜÀíÐÔ

    Ö§³ÖConsole/AUX Modem/Telnet/SSH2.0 ÃüÁîÐÐÅäÖÃ

    Ö§³ÖFTP¡¢TFTP¡¢XmodemÎļþÉÏÏÂÔØ¹ÜÀí

    Ö§³ÖSNMP V1/V2c/V3

    Ö§³ÖRMON

    Ö§³ÖNTPʱÖÓ

    Ö§³Ö¹ÊÕϺ󱨾¯ºÍ×Ô»Ö¸´

    Ö§³Öϵͳ¹¤×÷ÈÕÖ¾

    Ö§³ÖsFLOWÁ÷Á¿·ÖÎö

    ³ß´ç£¨¿íxÉîx¸ß£©(mm)

    442 x 595 x 219.5(5U)

    442 x 595 x 352.8(8U)

    442 x 821 x 797.3(18U)

    µçÔ´

    RG-PA1600I£º90~180V¹¦ÂÊ£º1200W£»180~264V¹¦ÂÊ£º1600W

    RG-PA600I£º90~180V¹¦ÂÊ£º600W£»180~264V¹¦ÂÊ£º600W

    RG-PD1600I£º-40.5V~ -75V¹¦ÂÊ£º1400W

    RG-PD600I£º-40.5V~ -75V¹¦ÂÊ£º600W

    RG-PA1600I-PL£º90~175V¹¦ÂÊ£º1000W£»176~264V¹¦ÂÊ£º1600W

    RG-PA3000I-PL£º90~175V¹¦ÂÊ£º2000W£»176~209V¹¦ÂÊ£º2500W£»210~264V¹¦ÂÊ£º3000W

    MTBF

    > 200,000 Сʱ

    ζÈ

    ¹¤×÷ζȣº0¡æ  µ½ 50¡æ

    ´æ´¢Î¶È£º-40¡æ µ½ 70¡æ

    ʪ¶È

    ¹¤×÷ʪ¶È£º10% µ½ 90% RH£¨ÎÞÀäÄý£©

    ´æ´¢Êª¶È£º5% µ½ 95% RH

    ¹¤×÷¸ß¶È/º£°Î

    -500~5000M

     

    Õ¹¿ªÏêϸ²ÎÊý

    ×ÊÔ´ÖÐÐÄ

    Ó¦Óð¸Àý
    ¼¼Êõ²©ÎÄ
    ÊÛºóÎĵµ

    ³£¼ûÎÊÌâ

    ÔÝÎÞÎÊÌ⣬ÎÒÒªÌáÎÊ
    Èç¹ûÄúÐèÒª¸ü¶à²úÆ·¼¼Êõ×Éѯ
    ¾ßÌåÐÔÄÜÄÜ·ñÂú×ãÄúµÄÒµÎñ·åÖµ£¿ÈçºÎ¹æ»®²¿ÊðÓëÅäÖã¿
    Á¢¼´×Éѯ

    ·µ»Ø¶¥²¿

    ÊÕÆð
    ÎĵµAIÖúÊÖ
    ÎĵµÆÀ¼Û
    ¸Ã×ÊÁÏÊÇ·ñ½â¾öÁËÄúµÄÎÊÌ⣿
    Äú¶Ôµ±Ç°Ò³ÃæµÄÂúÒâ¶ÈÈçºÎ£¿
    ²»Õ¦µÎ
    ·Ç³£ºÃ
    ÄúÂúÒâµÄÔ­ÒòÊÇ£¨¶àÑ¡£©£¿
    Äú¶ÔÎĵµÊÇ·ñ»¹ÓÐÆäËüµÄÎÊÌâ»ò½¨Ò飿
    Ϊ¾¡¿ì½â¾öÎÊÌ⣬ÇëÄúÁôÏÂÁªÏµ·½Ê½Òﱋȯ¸´
    ÓÊÏä
    ÊÖ»úºÅ
    ¸ÐлÄúµÄ·´À¡£¡
    ÇëÑ¡Ôñ·þÎñÏîÄ¿
    ¹Ø±Õ×Éѯҳ
    ÊÛǰ×Éѯ ÊÛǰ×Éѯ
    ÊÛǰ×Éѯ
    ÊÛºó·þÎñ ÊÛºó·þÎñ
    ÊÛºó·þÎñ
    Òâ¼û·´À¡ Òâ¼û·´À¡
    Òâ¼û·´À¡
    ¸ü¶àÁªÏµ·½Ê½
    ¡¾ÍøÕ¾µØÍ¼¡¿¡¾sitemap¡¿