Äܹ»ÊÊÓ¦²»Í¬ÍøÂç¹æÄ£µÄ¶Ë¿ÚÃܶȺÍÐÔÄÜÒªÇó£¬ÎªÔƼܹ¹ÍøÂ罨ÉèÌṩÓÐÁ¦µÄÉ豸±£ÕÏ£¬¿ÉÒÔ¸ù¾ÝÒµÎñÐèÒª²¿ÊðÔÚÊý¾ÝÖÐÐÄ¡¢³ÇÓòÍø¡¢Ô°ÇøÍø»òÊý¾ÝÖÐÐÄÓëÔ°ÇøÍøÈںϵij¡¾°¡£
ÀàÐÍ£º
²úÆ·ÌØÐÔ£º




*Ö§³ÖÑÆÖÕ¶Ë×Ô¶¯ÉÏÏß¹¦ÄÜ£¬¼´²å¼´Ó㬲¢Í¨¹ýȨÍþ»ú¹¹µÄÈÏÖ¤¼ì²â









|
¼¼Êõ²ÎÊý |
²ÎÊýÃèÊö |
|||
|
²úÆ·ÐͺŠ|
RG-N18007 |
RG-N18010 |
RG-N18012 |
RG-N18014 |
|
Ä£¿é²å²Û |
7¸ö£¨2¸öÓÃÓÚ¹ÜÀíÒýÇæÄ£¿é£© |
10¸ö£¨2¸öÓÃÓÚ¹ÜÀíÒýÇæÄ£¿é£©£¬ÁíÍâÖ§³Ö4¸ö¶ÀÁ¢½»»»Íø°å |
12¸ö£¨2¸öÓÃÓÚ¹ÜÀíÒýÇæÄ£¿é£©£¬ÁíÍâÖ§³Ö4¸ö¶ÀÁ¢½»»»Íø°å |
14¸ö£¨2¸öÓÃÓÚ¹ÜÀíÒýÇæÄ£¿é£©£¬ÁíÍâÖ§³Ö4¸ö¶ÀÁ¢½»»»Íø°å |
|
½»»»ÈÝÁ¿ |
325.8Tbps |
521.28Tbps |
780Tbps |
1042Tbps |
|
°üת·¢ËÙÂÊ |
60,000Mpps |
96,000Mpps |
120,000Mpps |
192,000Mpps/345600Mpps |
|
É豸ÐéÄ⻯ |
Ö§³ÖVSU(Virtual Switching Unit,ÐéÄâ½»»»µ¥Ôª)£¬Ö§³ÖÐéÄ⻯´ø¿í ≥2.56Tbps *Ö§³ÖVSD(Virtual Switch Device,ÐéÄâ½»»»É豸) |
|||
|
±ßÔµÐéÄâ½»»» |
Ö§³ÖVEPA£¨ÐéÄâÒÔÌ«Íø¶Ë¿Ú¾ÛºÏ£© Ö§³ÖÐéÄâ»ú²ßÂÔ×Ô¶¯Ç¨ÒÆ |
|||
|
SDN |
Ö§³ÖOpenFlow 1.3 |
|||
|
L2 ÌØÐÔ |
Ö§³ÖJumbo Frame Ö§³Ö802.1Q Ö§³ÖSTP¡¢RSTP¡¢MSTP Ö§³ÖSuper VLAN Ö§³ÖGVRP Ö§³ÖQinQ¡¢Áé»îQinQ¡¢QinQÖսᣨʵÏÖ±âÆ½»¯ÍøÂç¼Ü¹¹£© Ö§³ÖLLDP Ö§³ÖERPS£¨G.8032£© |
|||
|
ÐÐΪ¹Ü¿Ø |
Ö§³ÖURLÉó¼Æ Ö§³ÖÓû§¶¨Î» |
|||
|
¼¯ÖÐÈÏÖ¤ |
Ö§³Ö9W IPv4ºÍIPv6˫ջÓû§Í¬Ê±ÔÚÏߣ¬1200ÖÕ¶Ë/SµÄÉÏÏßËÙ¶È Ö§³Ö802.1x/Portal/Mac/IPoEµÈ¶àÖÖÈÏÖ¤·½Ê½ Ö§³ÖPortalÈÏÖ¤¡¢Ö§³ÖRADIUSºÍTACACS+Óû§µÇ¼ÈÏÖ¤ Ö§³Ö¶þ²ãPortal¡¢Èý²ãPortal½ÓÈëÈÏÖ¤ Ö§³Ö°´Á÷Á¿¼Æ·Ñ¡¢Á÷Á¿¿ØÖÆ¡¢¾«Ï¸»¯¹ÜÀí Ö§³ÖÅäºÏ·ÓÉÆ÷ʵÏÖPPPOEÈÏÖ¤¹¦ÄÜ |
|||
|
IPv4 ÌØÐÔ |
Ö§³Ö¾²Ì¬Â·ÓÉ¡¢RIP¡¢OSPF¡¢IS-IS¡¢BGP4 Ö§³ÖVRRP Ö§³ÖµÈ¼Û·ÓÉ Ö§³Ö²ßÂÔ·ÓÉ Ö§³ÖGREËíµÀ |
|||
|
IPv6 ÌØÐÔ |
Ö§³Ö¾²Ì¬Â·ÓÉ¡¢RIPng¡¢OSPFv3¡¢BGP4+¡¢IS-ISv6µÈ·ÓÉÐÒé Ö§³ÖVRRPv3 Ö§³ÖµÈ¼Û·ÓÉ Ö§³Ö²ßÂÔ·ÓÉ Ö§³ÖÊÖ¹¤ËíµÀ¡¢×Ô¶¯ËíµÀ¡¢ISATAPËíµÀ¡¢Ö§³ÖGREËíµÀµÈ |
|||
|
×é²¥ |
Ö§³ÖIGMP v1,v2,v3 Ö§³ÖIGMP Snooping Ö§³ÖIGMP Proxy Ö§³ÖPIM-DM¡¢PIM-SM¡¢PIM-SSMµÈ×鲥·ÓÉÐÒé Ö§³ÖMLD |
|||
|
MPLS |
Ö§³ÖMPLSת·¢ Ö§³Ö¿çÓòOPTION A/B/CÈýÖÖģʽ Ö§³ÖL3 MPLS VPN Ö§³ÖVPLS/VPWS |
|||
|
ACL |
Ö§³Ö±ê×¼¡¢À©Õ¹¡¢×¨¼Ò¼¶ACL Ö§³ÖACL 80 Ö§³ÖIPv6 ACL |
|||
|
QOS |
Ö§³Ö802.1P Ö§³ÖSP¡¢WRR¡¢DRR¡¢SP+WRR¡¢SP+DRRµÈ¶ÓÁе÷¶È»úÖÆ Ö§³ÖRED/WRED Ö§³Ö»ùÓÚ³ö¶Ë¿Ú/Èë¶Ë¿ÚµÄÏÞËÙ *Ö§³ÖHQoS |
|||
|
¾µÏñ |
Ö§³Ö¶à¶ÔÒ»¾µÏñ¡¢Ò»¶Ô¶à¾µÏñ¡¢»ùÓÚÁ÷µÄ¾µÏñ Ö§³ÖSPAN¡¢RSPANÔ¶³Ì¾µÏñ£¬Ö§³ÖVLANµÄ¾µÏñ |
|||
|
¿É¿¿ÐÔ |
¶ÀÁ¢µÄ½»»»Íø°åÓë¶ÀÁ¢µÄÖ÷¿Ø°åÉè¼Æ£¬ÊµÏÖת·¢Óë¿ØÖÆÆ½·ÖÀë Ö÷¿Ø°åÖ§³Ö1+1ÈßÓ౸·Ý ½»»»Íø°åÖ§³ÖN+1ÈßÓ౸·Ý µçÔ´¡¢·çÉÈÖ§³ÖN+MÈßÓ౸·Ý ±³°åÎÞÔ´Éè¼Æ£¬±ÜÃâµ¥µã¹ÊÕÏ ¸÷×é¼þÖ§³ÖÈȲå°Î Ö§³ÖÈȲ¹¶¡¹¦ÄÜ£¬¿ÉÔÚÏß½øÐв¹¶¡Éý¼¶ Ö§³ÖIP FRR Ö§³ÖISSU Ö§³ÖGR for OSPF/IS-IS/BGP/ Ö§³ÖBFD for VRRP/OSPF/BGP4/ISIS/ISISv6/MPLS/¾²Ì¬Â·ÓÉµÈ Ö§³Ö¶ÀÁ¢PoEµçÔ´²Û¹©µç£¬·ÀÖ¹ÒòPoE¹©µç¶øÓ°ÏìÆäËûÒµÎñÄ£¿é¹©µçÎȶ¨ÐÔ |
|||
|
°²È«ÐÔ |
Ö§³ÖNFPP£¨»ù´¡°²È«±£»¤²ßÂÔ£© Ö§³ÖCPP£¨CPU±£»¤£© Ö§³ÖDAI£¬¶Ë¿Ú°²È«£¬IP Source Guard Ö§³ÖuRPF Ö§³ÖµÇ¼ÈÏÖ¤¡¢¿ÚÁȫ Ö§³ÖÖ§³Öδ֪×é²¥²»ËÍCPU¡¢Ö§³Öδ֪µ¥²¥ÒÖÖÆ Ö§³ÖSSHv2£¬ÎªÓû§µÇ¼Ìṩ°²È«¼ÓÃÜͨµÀ Ö§³ÖITU-T Y.1731 Ö§³ÖEEE£¨802.3az£© |
|||
|
¹ÜÀíÐÔ |
Ö§³ÖConsole/AUX Modem/Telnet/SSH2.0 ÃüÁîÐÐÅäÖà ֧³ÖFTP¡¢TFTP¡¢XmodemÎļþÉÏÏÂÔØ¹ÜÀí Ö§³ÖSNMP V1/V2c/V3 Ö§³ÖRMON Ö§³ÖNTPʱÖÓ Ö§³Ö¹ÊÕϺ󱨾¯ºÍ×Ô»Ö¸´ Ö§³Öϵͳ¹¤×÷ÈÕÖ¾ Ö§³ÖsFLOWÁ÷Á¿·ÖÎö Ó²¼þÖ§³ÖDCMI£¨¹ú¼Ê±ê×¼Êý¾ÝÖÐÐĹÜÀí½Ó¿Ú£©£¬¿ÉʵÏÖÔ¶³Ì¶ÔÉ豸ÉÏ/ϵ硢¸´Î»¡¢×´Ì¬¼à¿ØµÈ²Ù×÷ |
|||
|
³ß´ç£¨¿íxÉîx¸ß£©(mm) |
442 x 598 x 352.8£¨8U£© |
442 x 836 x 797.3 (18U) |
442 x 725 x 708.4(16U) |
442 x 814 x 886.2(20U) |
|
µçÔ´ |
RG-PA1600I£º90~180V¹¦ÂÊ£º1200W£»180~264V¹¦ÂÊ£º1600W RG-PA600I£º 90~180V¹¦ÂÊ£º600W£»180~264V¹¦ÂÊ£º600W RG-PD1600I£º-40V~ -75V¹¦ÂÊ£º1400W RG-PD600I£º -40V~ -75V¹¦ÂÊ£º600W RG-PA1600I-PL£º90~175V¹¦ÂÊ£º1000W£»176~264V¹¦ÂÊ£º600W RG-PA3000I-PL£º90~175V¹¦ÂÊ£º200W£»176~209V¹¦ÂÊ£º2500W 210~264V ¹¦ÂÊ:3000W |
|||
|
MTBF |
> 200,000Сʱ |
|||
|
ÎÂ¶È |
¹¤×÷ζȣº0¡æ µ½ 50¡æ ´æ´¢Î¶ȣº-40¡æ µ½ 70¡æ |
|||
|
ʪ¶È |
¹¤×÷ʪ¶È£º10% µ½ 90% RH£¨ÎÞÀäÄý£© ´æ´¢Êª¶È£º5% µ½ 95% RH |
|||
|
¹¤×÷¸ß¶È/º£°Î |
-500~5000M |
|||
|
¶Ë¿Ú·ÀÀ× |
6KV |
|||
RG-N18000(NewtonÅ£¶Ù)ϵÁÐÔÆ¼Ü¹¹ÍøÂçºËÐĽ»»»»ú£¬Ñ¡ÔñRG-M18000-WS-EDÎÞÏß¿ØÖÆÄ£¿é¼´¿ÉÂú×ãÐèÇó
Ö§³Ö£¬²¢ÇÒ¿ÉÒÔÅäºÏRG-ONC¿ª·ÅÍøÂç¿ØÖÆÆ÷ʵÏÖÕûÍøÊýǧ¸öÍøÂçÉ豸½ÚµãµÄ¼¯ÖйÜÀíµ÷¶È¡£