¹«º£²Ê´¬¡¤6600(ÖйúÓÎ)¹Ù·½ÍøÕ¾

µã»÷ÏÂÔØ¡¶ÍòÕ×Ô°ÇøÒÔÌ«²Ê¹âÑо¿±¨¸æ¡·£¬½âËøÍòÕ×Ô°ÇøÍøÂ罨ÉèÖ¸ÄÏ
Á¢¼´ÏÂÔØ
ÎÞ¸Ð×¼Èë ÈËÎïͳ¹Ü Ø­ RG-SAM+5.X ÐÂÒ»´ú¸ßУAIÈÏ֤ƽ̨·¢²¼
Ô¤Ô¼Ö±²¥
²úÆ·
< ·µ»ØÖ÷²Ëµ¥
²úÆ·ÖÐÐÄ
²úÆ·
ºÏ×÷»ï°é
·µ»ØÖ÷²Ëµ¥
Ñ¡ÔñÇøÓò/ÓïÑÔ
RG-IS2706G
RG-IS2706G
RG-IS2706G
RG-IS2706G
¼ÓÔØÖÐ...0%
ͼƬ

4¿ÚǧÕ×µç½ÓÈë½»»»»ú£¬2¸ö1000BASE-X SFP¹â¿Ú£¬RG-IS2706G

ÄÜÂú×ãÆ½°²³ÇÊС¢ÖÇÄܽ»Í¨¡¢ÊÒÍâ¼à¿ØºÍÆäËû¶ñÁÓ»·¾³ÖеIJ¿ÊðÒªÇó

²úÆ·ÌØÐÔ£º

  • ¸ßÆ·ÖÊÓ²¼þÉè¼Æ¡¢Îȶ¨µÄÉ豸ÐÔÄÜ
  • ÐéÄ⻯¼¼Êõ
  • ·á¸»µÄÍøÂ繦ÄÜÓë°²È«ÌØÐÔ
  • Áé»îµÄ×éÍø£¬¼òÒ׵ĹÜÀí
Á¢¼´×Éѯ

¸ßÆ·ÖÊÓ²¼þÉè¼Æ¡¢Îȶ¨µÄÉ豸ÐÔÄÜ

¸ßÆ·ÖÊÓ²¼þÉè¼Æ¡£×ñÑ­¹¤Òµ¼¶Éè¼Æ¹æ·¶£¬²ÉÓùú¼Ê´ó³§Ö÷Á÷³ÉÊ칤ҵ¼¶Ð¾Æ¬¡¢¸ßÐÔÄܹ¤Òµ¼¶ CPU¡¢¹¤Òµ¼¶µçÔ´Ä£¿éºÍÂÁºÏ½ðÍâ¿Ç£¬±£Ö¤²úÆ·µÄ¹¤Òµ¼¶Æ·ÖÊ¡£

²ÉÓÃÎÞ·çÉÈÉ¢Èȵç·Éè¼Æ¡¢Ö§³Ö-40~85ºC¹¤×÷»·¾³Î¶ȡ¢IP40 ·À»¤µÈ¼¶¡¢·ÀÀ×µçѹ>=8KV¡¢·ÀÕñ¶¯±£»¤µçÔ´Éè¼Æ¡¢µç´Å¸ÉÈÅËļ¶±ê×¼¡¢Äͳå»÷ºÍÕñ¶¯£¬É豸¼´±ãÔÚ¶ñÁÓ»·¾³ÖÐÒ²ÄÜÎȶ¨¿É¿¿µÄÔËÐС£

ÐéÄ⻯¼¼Êõ

Ö§³ÖVSU£¨Virtual Switch Unit£©¼´ÐéÄâ½»»»µ¥Ôª¼¼Êõ¡£Í¨¹ý¾ÛºÏÁ´Â·Á¬½Ó£¬×î¶à¿É½«8̨ÎïÀíÉ豸ÐéÄâΪһ̨Âß¼­ÉÏͳһµÄÉ豸£¬Ê¹ÆäÄܹ»ÊµÏÖͳһµÄÔËÐУ¬ÀûÓõ¥Ò»IPµØÖ·¡¢µ¥Ò»Telnet½ø³Ì¡¢µ¥Ò»ÃüÁîÐнӿÚ(CLI)¡¢×Ô¶¯°æ±¾¼ì²é¡¢×Ô¶¯ÅäÖõÈÌØÐÔ¼ò»¯Á˹ÜÀí¡£

·á¸»µÄÍøÂ繦ÄÜÓë°²È«ÌØÐÔ

Ö§³ÖVLAN¡¢STP/RSTP ¡¢ERPS¡¢×é²¥¡¢¶Ë¿Ú¾µÏñ¡¢QoS¡¢¶Ë¿Ú°²È«¡¢¹ã²¥·ç±©ÒÖÖÆµÈ¶þ²ãÌØÐÔ£»Ö§³Ö¾²Ì¬Â·ÓɵÈÈý²ãÍøÂçЭÒé¡£

ͨ¹ý¶àÖÖÄÚÔڵݲȫ»úÖÆ¿ÉÓÐЧ·ÀÖ¹ºÍ¿ØÖƲ¡¶¾´«²¥ºÍÍøÂçÁ÷Á¿¹¥»÷£¬¿ØÖÆ·Ç·¨Óû§Ê¹ÓÃÍøÂ磬±£Ö¤ºÏ·¨Óû§ºÏÀí»¯Ê¹ÓÃÍøÂ磬Èç¶Ë¿Ú¾²Ì¬ºÍ¶¯Ì¬µÄ°²È«°ó¶¨¡¢¶Ë¿Ú¸ôÀë¡¢¶àÖÖÀàÐ͵ÄÓ²¼þACL¿ØÖÆ¡¢»ùÓÚÊý¾ÝÁ÷µÄ´ø¿íÏÞËÙ¡¢Óû§½ÓÈë¿ØÖÆµÄ¶àÔªËØ°ó¶¨µÈ£¬Âú×ãÄúÍøÂç¶ÔÉ豸½ÓÈëµÄ°²È«¿ØÖÆ¡£

»ù´¡ÍøÂç±£»¤£¨NFPP£©Í¨¹ý½«±¨ÎÄ·ÖÀàÏÞËÙ£¨¹ÜÀíÀࡢת·¢ÀࡢЭÒéÀࣩ£¬²¢¶Ô±¨ÎĽøÐй¥»÷¼à²â£¬Ë«Öر£Õϱ£»¤CPUºÍÐŵÀ´ø¿í×ÊÔ´ÃâÊܹ¥»÷·³ÈÅ£¬±£Ö¤±¨ÎĵÄÕý³£×ª·¢ÒÔ¼°Ð­Òé״̬µÄÕý³££¬Î¬»¤ÍøÂçµÄÎȶ¨¡£

Áé»îµÄ×éÍø£¬¼òÒ׵ĹÜÀí

Ö§³Ö´«Í³µÄÐÇÐÎ×éÍøÄ£Ê½¡¢Í¬Ê±Ò²Ö§³ÖÒÔÌ«Íø¶à»·±£»¤¼¼Êõ£¨ERPS£©ÊµÏÖ»·Ðη½Ê½×éÍø£¬¸Ã×éÍø·½Ê½¾ßÓкܸߵÄÈßÓà¿É¿¿ÐÔ£¬Ò»µ©»·Â·ÓÐÒ»½Úµã³öÏÖ¹ÊÕÏ£¬¿ÉÒÔ´ÓÁíÒ»¶Ë½øÐÐÊý¾Ýת·¢£¬Çл»Ê±¼ä≤20ms¡£Óë´Ëͬʱ£¬»·Íø·½Ê½Ïà±ÈÐÇÐÎ×éÍø¸ü½ÚÊ¡¹âÏË£¬¿ÉÒÔΪÄú½Úʡһ¶¨µÄ½¨Éè³É±¾¡£

²ÉÓÃÁé»îµÄǧÕ×µç¿Ú+¹â¿Ú£¨·Ç¸´Ó㩵ÄÐÎʽ£¬·½±ãÓû§¸ù¾ÝÍøÂç¼Ü¹¹Áé»îÑ¡ÔñÁ¬½ÓÐÎʽ¡£

ͬʱ֧³ÖʹÓô«Í³CLIÃüÁîÐз½Ê½ºÍWebͼÐλ¯½çÃæ·½Ê½ÅäÖý»»»»ú£¬ÎÞÐèÁ˽⸴ÔÓµÄÃüÁîÐкÍÖÕ¶ËÄ£Äâ³ÌÐò£¬ÔÊÐí¼òµ¥¡¢¿ìËÙµÄÅäÖý»»»»ú£¬´Ó¶ø½µµÍ²¿ÊðÄѶÈ¡£

Syslog·½±ã¸÷ÖÖÈÕÖ¾ÐÅÏ¢µÄͳһÊÕ¼¯¡¢Î¬»¤¡¢·ÖÎö¡¢¹ÊÕ϶¨Î»¡¢±¸·Ý£¬±ãÓÚ¹ÜÀíÔ±½øÐÐÍøÂçά»¤ºÍ¹ÜÀí¡£

¼¼Êõ²ÎÊý

²úÆ·ÐͺÅ

RG-IS2712G

RG-IS2712G-DC

RG-IS2706G

¹Ì»¯¶Ë¿Ú

8¸ö10/100/1000M µç¿Ú£»4¸ö1000BASE-X SFP¹â¿Ú

4¸ö10/100/1000M µç¿Ú£»2¸ö1000BASE-X SFP¹â¿Ú

À©Õ¹Ä£¿é

ÎÞ

¹ÜÀí¿Ú

1¸öConsole ¶Ë¿Ú

Ò»¼üÖØÆô

Ö§³ÖÒ»¼üÖØÆô

½»»»ÈÝÁ¿

128G

°üת·¢ËÙÂÊ

26.7Mpps

13.4Mpps

802.1q VLAN

4K

¹¤×÷»·¾³

¹¤×÷ζÈ-40¡«85¡æ

¹¤×÷ʪ¶È5¡«95%RH

·À»¤µÈ¼¶IP40

¶Ë¿Ú·ÀÀ×≥8KV

ƽ¾ùÎÞ¹ÊÕÏʱ¼ä£¨MTBF£©£º30ÄêÒÔÉÏ

µç´Å¸ÉÈÅ

ESD (IEC 61000-4-2)                  Level 4 (8K/15K)

RS (IEC 61000-4-3)                    Level 3 (10V/m)

EFT (IEC 61000-4-4)                  Level 3 (1V/2V)

CS (IEC 61000-4-6)                    Level 3 (10V/m)

PFMF (IEC 61000-4-8)                Level4£¨30A/m£©

Surge (IEC 61000-4-5)                Level 4+(6KV/2KV)

DIP (IEC 61000-4-11)                 Level3 (10V)

L2ЭÒé

G.8032 (ERPS)¡¢IEEE802.3¡¢IEEE802.3u¡¢IEEE802.3z ¡¢IEEE802.3x¡¢IEEE802.3ad¡¢IEEE802.1p¡¢

IEEE802.1x¡¢IEEE802.3ab¡¢IEEE802.1Q¡¢IEEE802.1d¡¢IEEE802.1w¡¢IEEE802.1s¡¢

IGMP Snooping v1/v2/v3

ACL

±ê×¼IP ACL£¨»ùÓÚIPµØÖ·µÄÓ²¼þACL£©

À©Õ¹IP ACL£¨»ùÓÚIPµØÖ·¡¢TCP/UDP¶Ë¿ÚºÅµÄÓ²¼þACL£©

MACÀ©Õ¹ACL£¨»ùÓÚÔ´MACµØÖ·¡¢Ä¿µÄMACµØÖ·ºÍ¿ÉÑ¡µÄÒÔÌ«ÍøÀàÐ͵ÄÓ²¼þACL£©»ùÓÚʱ¼äACL

ר¼Ò¼¶ACL £¨¿Éͬʱ»ùÓÚVLANºÅ¡¢ÒÔÌ«ÍøÀàÐÍ¡¢MACµØÖ·¡¢IPµØÖ·¡¢TCP/UDP¶Ë¿ÚºÅ¡¢Ð­ÒéÀàÐÍ¡¢Ê±¼äµÈÁé»î×éºÏµÄÓ²¼þACL£©

IPv6 ACL&QoS

Ö§³Ö»ùÓÚÔ´/Ä¿µÄIPv6µØÖ·¡¢Ô´/Ä¿µÄ¶Ë¿ÚµÄIPv6 ACLºÍIPv6 QoS

ÓÅÏȼ¶¶ÓÁÐ:8

°²È«ÌØÐÔ

Ö§³ÖIP¡¢MAC¡¢¶Ë¿ÚÈýÔªËØ°ó¶¨

Ö§³ÖIPv6¡¢MAC¡¢¶Ë¿ÚÈýÔªËØ°ó¶¨

¹ýÂË·Ç·¨µÄMACµØÖ·

Ö§³Ö»ùÓڶ˿ںÍMACµÄ802.1x

Ö§³ÖWEBÈÏÖ¤£¬ºÍ802.1X¡¢ARP-Check¡¢ACL¿Éͬʱ¿ªÆô

Ö§³ÖARP-Check

Ö§³ÖDAI

Ö§³ÖARP±¨ÎÄÏÞËÙ

Ö§³Ö¹ã²¥·ç±©ÒÖÖÆ

¹ÜÀíÔ±·Ö¼¶¹ÜÀíºÍ¿ÚÁî±£»¤

É豸µÇ½¹ÜÀíµÄAAA°²È«ÈÏÖ¤£¨IPv4/IPv6£©

Ö§³ÖSSH

Ö§³ÖBPDU Guard

Ö§³ÖDOS¹¥»÷·À»¤¡¢ARP¹¥»÷·À»¤¡¢ICMP¹¥»÷·À»¤

Ö§³Ö¶Ë¿Ú¸ôÀë¡¢¶Ë¿Ú°²È«

Ö§³Ö±¨¾¯¶Ë¿Ú¹¦ÄÜ

IP·ÓÉ

Ö§³Öȱʡ·ÓÉ£¬Ö§³ÖÖ÷»ú¼°Ö±Á¬Íø¶ÎµÄ¾²Ì¬Â·ÓÉ

IPv6ЭÒé

IPv6±àÖ·¡¢ÁÚ¾Ó·¢ÏÖЭÒ飨ND£©¡¢ICMPv6¡¢IPv6 Ping¡¢IPv6 TracertµÈ

¹ÜÀíÌØÐÔ

SNMPv1/v2c/v3¡¢CLI(Telnet/Console)¡¢RMON(1£¬2£¬3£¬9)¡¢SSH¡¢Syslog¡¢NTP/SNTP¡¢Web

»úе½á¹¹

³ß´ç£º52*115*160mm (W×H×D)

°²×°·½Ê½: DIN¿¨¹ìʽ»ò±Ú¹Òʽ

µçÔ´

½»Á÷£¨AC£©ÊäÈ룺

¶î¶¨µçѹ·¶Î§£º100-240V~

×î´óµçѹ·¶Î§£º90-264V~

ƵÂÊ£º50-60Hz

¶î¶¨µçÁ÷£º0.4A

 

¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺

¶î¶¨µçѹ·¶Î§£º140-340VDC

×î´óµçѹ·¶Î§£º130-370VDC

¶î¶¨µçÁ÷£º0.4A

 

Ö±Á÷£¨DC£©ÊäÈ룺

24DCW£¨18-72VDC£©&48DCW£¨18-72VDC£©

Ë«ÈßÓàÊäÈë

¹¦ºÄ

Õû»ú¹¦ºÄ≤11.5W

Õû»ú¹¦ºÄ≤8W

É¢ÈÈ

ÎÞ·çÉÈÉè¼Æ£¬¸ßЧɢÈÈÆ¬É¢ÈÈ

 

Õ¹¿ªÏêϸ²ÎÊý

Ó¦Óó¡¾°

×ÊÔ´ÖÐÐÄ

ÓªÏú×ÊÁÏ
Ó¦Óð¸Àý
¼¼Êõ²©ÎÄ
ÊÛºóÎĵµ

³£¼ûÎÊÌâ

ÎÒÒªÌáÎÊ
È«²¿
¿íÎÂ(1)
¹«º£²Ê´¬¡¤6600 2022Äê07ÔÂ25ÈÕ
RG-IS2700GϵÁй¤ÒµÒÔÌ«Íø½»»»»úÊÇ·ñÊÇ¿íν»»»»ú£¿
ÓÐÓÃ 29 ÎÞÓÃ 1

ÊǵÄ£¬¸Ã¿î½»»»»úΪÎÒ˾¹¤Òµ½»»»»ú¡£¹¤Òµ½»»»»ú¶¼ÊÇ¿íÎÂÉè¼ÆµÄ¡£

c**** 2023Äê08ÔÂ15ÈÕ
¹¤Òµ½»»»»úÓëÆäËûµÄ½»»»»úÓÐʲô²»Í¬Âð£¿
ÓÐÓÃ 23 ÎÞÓÃ 1
¹¤Òµ½»»»»úÊÇרÓÃÓÚ¹¤Òµ¿ØÖÆÁìÓòµÄ¹¤Òµ¼¶½»»»»ú£¬¹¤ÒµÒÔÌ«Íø½»»»»úÒ²ÊÇÖ¸Ëü£¬Òò´ËÓÉÓÚÓ¦Óó¡ºÏ²»Í¬£¬¹¤Òµ½»»»»úÓëÆäËûÆÕͨµÄ½»»»»úÔÚÍâ¹ÛºÍ°²×°ÐÎʽÉÏÓÐÇø±ð£¬Í¬Ê±ÐÔÄܺ͹¦ÄÜÒ²ÓÐËù²»Í¬£¬¹¤Òµ½»»»»ú¶Ô·ÀË®¡¢·À³¾¡¢¿¹¸ÉÈŵÄÒªÇó½Ï¸ß£¬ÒªÓÐÄܹ»³¤Ê±¼äÔËÐеÄÄÜÁ¦£¬Í¬Ê±²»ÖжÏ¡¢ÑÓʱµÍ£¬¶øÒ»°ãµÄ½»»»»úûÓÐÕâô¸ßµÄÒªÇó¡£
Õ¹¿ªÈ«²¿
Èç¹ûÄúÐèÒª¸ü¶à²úÆ·¼¼Êõ×Éѯ
¾ßÌåÐÔÄÜÄÜ·ñÂú×ãÄúµÄÒµÎñ·åÖµ£¿ÈçºÎ¹æ»®²¿ÊðÓëÅäÖã¿
Á¢¼´×Éѯ

·µ»Ø¶¥²¿

ÊÕÆð
ÎĵµAIÖúÊÖ
ÎĵµÆÀ¼Û
¸Ã×ÊÁÏÊÇ·ñ½â¾öÁËÄúµÄÎÊÌ⣿
Äú¶Ôµ±Ç°Ò³ÃæµÄÂúÒâ¶ÈÈçºÎ£¿
²»Õ¦µÎ
·Ç³£ºÃ
ÄúÂúÒâµÄÔ­ÒòÊÇ£¨¶àÑ¡£©£¿
Äú¶ÔÎĵµÊÇ·ñ»¹ÓÐÆäËüµÄÎÊÌâ»ò½¨Ò飿
Ϊ¾¡¿ì½â¾öÎÊÌ⣬ÇëÄúÁôÏÂÁªÏµ·½Ê½Òﱋȯ¸´
ÓÊÏä
ÊÖ»úºÅ
¸ÐлÄúµÄ·´À¡£¡
ÇëÑ¡Ôñ·þÎñÏîÄ¿
¹Ø±Õ×Éѯҳ
ÊÛǰ×Éѯ ÊÛǰ×Éѯ
ÊÛǰ×Éѯ
ÊÛºó·þÎñ ÊÛºó·þÎñ
ÊÛºó·þÎñ
Òâ¼û·´À¡ Òâ¼û·´À¡
Òâ¼û·´À¡
¸ü¶àÁªÏµ·½Ê½
¡¾ÍøÕ¾µØÍ¼¡¿¡¾sitemap¡¿