ÄÜÂú×ãÆ½°²³ÇÊС¢ÖÇÄܽ»Í¨¡¢ÊÒÍâ¼à¿ØºÍÆäËû¶ñÁÓ»·¾³ÖеIJ¿ÊðÒªÇó
²úÆ·ÌØÐÔ£º
¸ßÆ·ÖÊÓ²¼þÉè¼Æ¡¢Îȶ¨µÄÉ豸ÐÔÄÜ
¸ßÆ·ÖÊÓ²¼þÉè¼Æ¡£×ñѹ¤Òµ¼¶Éè¼Æ¹æ·¶£¬²ÉÓùú¼Ê´ó³§Ö÷Á÷³ÉÊ칤ҵ¼¶Ð¾Æ¬¡¢¸ßÐÔÄܹ¤Òµ¼¶ CPU¡¢¹¤Òµ¼¶µçÔ´Ä£¿éºÍÂÁºÏ½ðÍâ¿Ç£¬±£Ö¤²úÆ·µÄ¹¤Òµ¼¶Æ·ÖÊ¡£
²ÉÓÃÎÞ·çÉÈÉ¢Èȵç·Éè¼Æ¡¢Ö§³Ö-40~85ºC¹¤×÷»·¾³Î¶ȡ¢IP40 ·À»¤µÈ¼¶¡¢·ÀÀ×µçѹ>=8KV¡¢·ÀÕñ¶¯±£»¤µçÔ´Éè¼Æ¡¢µç´Å¸ÉÈÅËļ¶±ê×¼¡¢Äͳå»÷ºÍÕñ¶¯£¬É豸¼´±ãÔÚ¶ñÁÓ»·¾³ÖÐÒ²ÄÜÎȶ¨¿É¿¿µÄÔËÐС£
ÐéÄ⻯¼¼Êõ
Ö§³ÖVSU£¨Virtual Switch Unit£©¼´ÐéÄâ½»»»µ¥Ôª¼¼Êõ¡£Í¨¹ý¾ÛºÏÁ´Â·Á¬½Ó£¬×î¶à¿É½«8̨ÎïÀíÉ豸ÐéÄâΪһ̨Âß¼ÉÏͳһµÄÉ豸£¬Ê¹ÆäÄܹ»ÊµÏÖͳһµÄÔËÐУ¬ÀûÓõ¥Ò»IPµØÖ·¡¢µ¥Ò»Telnet½ø³Ì¡¢µ¥Ò»ÃüÁîÐнӿÚ(CLI)¡¢×Ô¶¯°æ±¾¼ì²é¡¢×Ô¶¯ÅäÖõÈÌØÐÔ¼ò»¯Á˹ÜÀí¡£
·á¸»µÄÍøÂ繦ÄÜÓë°²È«ÌØÐÔ
Ö§³ÖVLAN¡¢STP/RSTP ¡¢ERPS¡¢×é²¥¡¢¶Ë¿Ú¾µÏñ¡¢QoS¡¢¶Ë¿Ú°²È«¡¢¹ã²¥·ç±©ÒÖÖÆµÈ¶þ²ãÌØÐÔ£»Ö§³Ö¾²Ì¬Â·ÓɵÈÈý²ãÍøÂçÐÒé¡£
ͨ¹ý¶àÖÖÄÚÔڵݲȫ»úÖÆ¿ÉÓÐЧ·ÀÖ¹ºÍ¿ØÖƲ¡¶¾´«²¥ºÍÍøÂçÁ÷Á¿¹¥»÷£¬¿ØÖÆ·Ç·¨Óû§Ê¹ÓÃÍøÂ磬±£Ö¤ºÏ·¨Óû§ºÏÀí»¯Ê¹ÓÃÍøÂ磬Èç¶Ë¿Ú¾²Ì¬ºÍ¶¯Ì¬µÄ°²È«°ó¶¨¡¢¶Ë¿Ú¸ôÀë¡¢¶àÖÖÀàÐ͵ÄÓ²¼þACL¿ØÖÆ¡¢»ùÓÚÊý¾ÝÁ÷µÄ´ø¿íÏÞËÙ¡¢Óû§½ÓÈë¿ØÖÆµÄ¶àÔªËØ°ó¶¨µÈ£¬Âú×ãÄúÍøÂç¶ÔÉ豸½ÓÈëµÄ°²È«¿ØÖÆ¡£
»ù´¡ÍøÂç±£»¤£¨NFPP£©Í¨¹ý½«±¨ÎÄ·ÖÀàÏÞËÙ£¨¹ÜÀíÀࡢת·¢Àà¡¢ÐÒéÀࣩ£¬²¢¶Ô±¨ÎĽøÐй¥»÷¼à²â£¬Ë«Öر£Õϱ£»¤CPUºÍÐŵÀ´ø¿í×ÊÔ´ÃâÊܹ¥»÷·³ÈÅ£¬±£Ö¤±¨ÎĵÄÕý³£×ª·¢ÒÔ¼°ÐÒé״̬µÄÕý³££¬Î¬»¤ÍøÂçµÄÎȶ¨¡£
Áé»îµÄ×éÍø£¬¼òÒ׵ĹÜÀí
Ö§³Ö´«Í³µÄÐÇÐÎ×éÍøÄ£Ê½¡¢Í¬Ê±Ò²Ö§³ÖÒÔÌ«Íø¶à»·±£»¤¼¼Êõ£¨ERPS£©ÊµÏÖ»·Ðη½Ê½×éÍø£¬¸Ã×éÍø·½Ê½¾ßÓкܸߵÄÈßÓà¿É¿¿ÐÔ£¬Ò»µ©»·Â·ÓÐÒ»½Úµã³öÏÖ¹ÊÕÏ£¬¿ÉÒÔ´ÓÁíÒ»¶Ë½øÐÐÊý¾Ýת·¢£¬Çл»Ê±¼ä≤20ms¡£Óë´Ëͬʱ£¬»·Íø·½Ê½Ïà±ÈÐÇÐÎ×éÍø¸ü½ÚÊ¡¹âÏË£¬¿ÉÒÔΪÄú½Úʡһ¶¨µÄ½¨Éè³É±¾¡£
²ÉÓÃÁé»îµÄǧÕ×µç¿Ú+¹â¿Ú£¨·Ç¸´Ó㩵ÄÐÎʽ£¬·½±ãÓû§¸ù¾ÝÍøÂç¼Ü¹¹Áé»îÑ¡ÔñÁ¬½ÓÐÎʽ¡£
ͬʱ֧³ÖʹÓô«Í³CLIÃüÁîÐз½Ê½ºÍWebͼÐλ¯½çÃæ·½Ê½ÅäÖý»»»»ú£¬ÎÞÐèÁ˽⸴ÔÓµÄÃüÁîÐкÍÖÕ¶ËÄ£Äâ³ÌÐò£¬ÔÊÐí¼òµ¥¡¢¿ìËÙµÄÅäÖý»»»»ú£¬´Ó¶ø½µµÍ²¿ÊðÄѶȡ£
Syslog·½±ã¸÷ÖÖÈÕÖ¾ÐÅÏ¢µÄͳһÊÕ¼¯¡¢Î¬»¤¡¢·ÖÎö¡¢¹ÊÕ϶¨Î»¡¢±¸·Ý£¬±ãÓÚ¹ÜÀíÔ±½øÐÐÍøÂçά»¤ºÍ¹ÜÀí¡£
|
²úÆ·ÐͺŠ|
RG-IS2712G RG-IS2712G-DC |
RG-IS2706G |
|
|
¹Ì»¯¶Ë¿Ú |
8¸ö10/100/1000M µç¿Ú£»4¸ö1000BASE-X SFP¹â¿Ú |
4¸ö10/100/1000M µç¿Ú£»2¸ö1000BASE-X SFP¹â¿Ú |
|
|
À©Õ¹Ä£¿é |
ÎÞ |
||
|
¹ÜÀí¿Ú |
1¸öConsole ¶Ë¿Ú |
||
|
Ò»¼üÖØÆô |
Ö§³ÖÒ»¼üÖØÆô |
||
|
½»»»ÈÝÁ¿ |
128G |
||
|
°üת·¢ËÙÂÊ |
26.7Mpps |
13.4Mpps |
|
|
802.1q VLAN |
4K |
||
|
¹¤×÷»·¾³ |
¹¤×÷ζÈ-40¡«85¡æ |
||
|
¹¤×÷ʪ¶È5¡«95%RH |
|||
|
·À»¤µÈ¼¶IP40 |
|||
|
¶Ë¿Ú·ÀÀ×≥8KV |
|||
|
ƽ¾ùÎÞ¹ÊÕÏʱ¼ä£¨MTBF£©£º30ÄêÒÔÉÏ |
|||
|
µç´Å¸ÉÈÅ |
ESD (IEC 61000-4-2) Level 4 (8K/15K) RS (IEC 61000-4-3) Level 3 (10V/m) EFT (IEC 61000-4-4) Level 3 (1V/2V) CS (IEC 61000-4-6) Level 3 (10V/m) PFMF (IEC 61000-4-8) Level4£¨30A/m£© Surge (IEC 61000-4-5) Level 4+(6KV/2KV) DIP (IEC 61000-4-11) Level3 (10V) |
||
|
L2ÐÒé |
G.8032 (ERPS)¡¢IEEE802.3¡¢IEEE802.3u¡¢IEEE802.3z ¡¢IEEE802.3x¡¢IEEE802.3ad¡¢IEEE802.1p¡¢ IEEE802.1x¡¢IEEE802.3ab¡¢IEEE802.1Q¡¢IEEE802.1d¡¢IEEE802.1w¡¢IEEE802.1s¡¢ IGMP Snooping v1/v2/v3 |
||
|
ACL |
±ê×¼IP ACL£¨»ùÓÚIPµØÖ·µÄÓ²¼þACL£© À©Õ¹IP ACL£¨»ùÓÚIPµØÖ·¡¢TCP/UDP¶Ë¿ÚºÅµÄÓ²¼þACL£© MACÀ©Õ¹ACL£¨»ùÓÚÔ´MACµØÖ·¡¢Ä¿µÄMACµØÖ·ºÍ¿ÉÑ¡µÄÒÔÌ«ÍøÀàÐ͵ÄÓ²¼þACL£©»ùÓÚʱ¼äACL ר¼Ò¼¶ACL £¨¿Éͬʱ»ùÓÚVLANºÅ¡¢ÒÔÌ«ÍøÀàÐÍ¡¢MACµØÖ·¡¢IPµØÖ·¡¢TCP/UDP¶Ë¿ÚºÅ¡¢ÐÒéÀàÐÍ¡¢Ê±¼äµÈÁé»î×éºÏµÄÓ²¼þACL£© |
||
|
IPv6 ACL&QoS |
Ö§³Ö»ùÓÚÔ´/Ä¿µÄIPv6µØÖ·¡¢Ô´/Ä¿µÄ¶Ë¿ÚµÄIPv6 ACLºÍIPv6 QoS ÓÅÏȼ¶¶ÓÁÐ:8 |
||
|
°²È«ÌØÐÔ |
Ö§³ÖIP¡¢MAC¡¢¶Ë¿ÚÈýÔªËØ°ó¶¨ Ö§³ÖIPv6¡¢MAC¡¢¶Ë¿ÚÈýÔªËØ°ó¶¨ ¹ýÂË·Ç·¨µÄMACµØÖ· Ö§³Ö»ùÓڶ˿ںÍMACµÄ802.1x Ö§³ÖWEBÈÏÖ¤£¬ºÍ802.1X¡¢ARP-Check¡¢ACL¿Éͬʱ¿ªÆô Ö§³ÖARP-Check Ö§³ÖDAI Ö§³ÖARP±¨ÎÄÏÞËÙ Ö§³Ö¹ã²¥·ç±©ÒÖÖÆ ¹ÜÀíÔ±·Ö¼¶¹ÜÀíºÍ¿ÚÁî±£»¤ É豸µÇ½¹ÜÀíµÄAAA°²È«ÈÏÖ¤£¨IPv4/IPv6£© Ö§³ÖSSH Ö§³ÖBPDU Guard Ö§³ÖDOS¹¥»÷·À»¤¡¢ARP¹¥»÷·À»¤¡¢ICMP¹¥»÷·À»¤ Ö§³Ö¶Ë¿Ú¸ôÀë¡¢¶Ë¿Ú°²È« Ö§³Ö±¨¾¯¶Ë¿Ú¹¦ÄÜ |
||
|
IP·ÓÉ |
Ö§³Öȱʡ·ÓÉ£¬Ö§³ÖÖ÷»ú¼°Ö±Á¬Íø¶ÎµÄ¾²Ì¬Â·ÓÉ |
||
|
IPv6ÐÒé |
IPv6±àÖ·¡¢ÁÚ¾Ó·¢ÏÖÐÒ飨ND£©¡¢ICMPv6¡¢IPv6 Ping¡¢IPv6 TracertµÈ |
||
|
¹ÜÀíÌØÐÔ |
SNMPv1/v2c/v3¡¢CLI(Telnet/Console)¡¢RMON(1£¬2£¬3£¬9)¡¢SSH¡¢Syslog¡¢NTP/SNTP¡¢Web |
||
|
»úе½á¹¹ |
³ß´ç£º52*115*160mm (W×H×D) |
||
|
°²×°·½Ê½: DIN¿¨¹ìʽ»ò±Ú¹Òʽ |
|||
|
µçÔ´ |
½»Á÷£¨AC£©ÊäÈ룺 ¶î¶¨µçѹ·¶Î§£º100-240V~ ×î´óµçѹ·¶Î§£º90-264V~ ƵÂÊ£º50-60Hz ¶î¶¨µçÁ÷£º0.4A
¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺 ¶î¶¨µçѹ·¶Î§£º140-340VDC ×î´óµçѹ·¶Î§£º130-370VDC ¶î¶¨µçÁ÷£º0.4A
Ö±Á÷£¨DC£©ÊäÈ룺 24DCW£¨18-72VDC£©&48DCW£¨18-72VDC£© Ë«ÈßÓàÊäÈë |
||
|
¹¦ºÄ |
Õû»ú¹¦ºÄ≤11.5W |
Õû»ú¹¦ºÄ≤8W |
|
|
É¢ÈÈ |
ÎÞ·çÉÈÉè¼Æ£¬¸ßЧɢÈÈÆ¬É¢ÈÈ |
||
Êǵģ¬¸Ã¿î½»»»»úΪÎÒ˾¹¤Òµ½»»»»ú¡£¹¤Òµ½»»»»ú¶¼ÊÇ¿íÎÂÉè¼ÆµÄ¡£